Download Print this page

Wiring Instructions - JBL Control 47C/T User Manual

Control contractor 40 series
Hide thumbs Also See for Control 47C/T:

Advertisement

Control Contractor 40 Series in-ceiling loudspeakers
include Euroblock locking input connectors that allow the
system to be "pre-wired".
Connecting the Wiring to the Euroblock
-- Connect the wiring to the removable
locking connector that is INCLUDED with
the speaker by stripping the insulation back
about 5 mm (about 3/16 inch), inserting
the bare end of wire into the connector and
screwing down the hold-down screw until
tight using a small flatblade screwdriver.
Tighten any unused screws to avoid
vibration. Using terminal block connectors
allows the system to be pre-wired before final installation
of the product.
When
wiring
Control
loudspeakers,
always
practices
in
accordance
codes and regulations.
Connecting
the
Input
Contractor 40 Series Loudspeakers -- The input terminal
cover on all Control Contractor 40 Series are fitted with a
conduit connector for securing wiring conduit to and from
the unit. To wire the unit:
1. Loosen the screw on top of the input terminal cover and
then remove (and save) the input terminal cover screw on
the side of the can.
2. Swing open the input terminal cover and remove the
euroblock connector.
+
-
+
Loop
IN
IN
Thru
3. Insert the bare ends of wire into the Euroblock connector
and secure the wires with the hold-down screws. (see
Connecting the Wiring to the Euroblock)
Euroblock
Connector
Conduit
Connector

WIRING INSTRUCTIONS

2-pin Connector
Contractor
40
use
proper
electrical
with
your
area's
Terminal
Block
on
-
Loop
Thru
4. Loosen the conduit
connector on the input
terminal cover and insert
the
wired
euroblock
connector
the
conduit
connector
+
-
+
-
opening.
Connect
Sat 3
Sat 4
euroblock to the matching
receptacle.
+
-
+
-
Sat 1
Sat 2
+
-
+
-
Loop
Loop
IN
IN
Thru
Thru
5. Close the input terminal cover and tighten the terminal
cover screws.
6. Allowing sufficient strain relief slack for the input wiring
and re-tighten the conduit connector on the terminal
cover.
NOTE: The input terminal
cover on Control Contractor
40
Series
includes a .75 in (19 mm)
knockout for an additional
conduit clamp. This knockout
point can be used in addition
to the conduit connector
located on the top of the can
and is useful for wiring loop-
Series
thru runs or when access is
wiring
limited on the top of the can.
building
Guide to Connection Pins on Control 40 Loudspeakers
-- There are two (2) removable locking input connectors
Control
with two (2) terminals on each for the Control 42C, Control
47C/T, Control 47LP and Control 47HC and six (6) terminals
on the Control 40CS/T. The pin functions are listed on the
label located on the can.
Control 42C:
-
+
IN
IN
Control 47C/T, LP & HC:
-
+
IN
IN
+
-
Loop
Loop
Thru
Thru
To wire Control 40 Series loudspeakers simply connect
the positive wire to the "+" pin and connect the negative
through
wire to the "-" pin. The "IN" pins are paralled to the "LOOP
THRU" pins (+ and - respectively) inside the loudspeaker.
the
The "Loop Thru" pins allow a parallel connection to an
additional loudspeaker.
To select the operating mode or desired output tap of the
loudspeaker, simply rotate the tap selector switch located
on the front of the baffle to the desired setting.
Note: Both 70V/(100V) connections and low impedance
connections are made via the same input pins. When
using the transformer tap selections, be sure that the
power amplifier is set on 70V/(100V) mode and the leads
feeding the system are connected to 70V/(100V) outputs
on the amplifier.
JBL Professional Control Contractor 40 Series
loudspeakers
-
-
+
+
Loop
Loop
IN
IN
Thru
Thru
Control 40CS/T:
+
-
+
Loop
Loop
Sat 3
Thru
Thru
+
Sat 1
+
IN
-
+
+
Sat 3
Sat 4
-
+
+
Sat 1
Sat 2
-
+
+
Loop
IN
IN
Thru
Knockout
-
+
-
Sat 4
-
+
-
Sat 2
Loo
-
-
+
Thru
Loop
Loop
IN
Thru
Thru
-
-
-
Loop
Thru
5
+
IN
+

Hide quick links:

Advertisement

loading