Arm/Disarm Diagnostics; System Status Chips; Table Of Zones - Python 460HP Installation Manual

Car security
Hide thumbs Also See for 460HP:
Table of Contents

Advertisement

Diagnostics
The system's microprocessor monitors and reports all active and violated zones when arming and
disarming. LED flashes indicate the active or violated zone; siren chirps indicate system status.

Arm/Disarm Diagnostics

The number of siren chirps will indicate the status of the alarm when arming and disarming. For
information on which zone is active or has been violated refer to the Table of Zones.
System Status Chirps
Action
Number of Chirps
Arm
1
Arm
1 (3 second delay), 1
Disarm
2
Disarm
4
Disarm
5

Table of Zones

Zone No.
Trigger type
1
Instant
2
On-board shock sensor
3
Two-stage, progresses from
4
Multiplexed Input
5
Two-stage (similar to doors)
NOTE: The Warn Away® response does not report on the LED.
24
Description
System armed
System armed with Bypass Notification
System disarmed
System disarmed with Tamper Alert
System disarmed NPC® active
Input description
H1/6 BLUE - Connect to optional hood/trunk pins.
Heavy impact detected by the on-board shock
sensor.
Door switch circuit. H1/5 GREEN or H1/7
VIOLET warning to full alarm
BLUE and GREEN wires of optional sensor
plug. Inputs shorter than 0.8 seconds will trigger
a Warn Away response, while inputs longer than
0.8 seconds will instantly trigger a full alarm
sequence and report Zone 4.
Ignition input. H1/9 YELLOW.
©
2002
Directed Electronics, Inc.

Advertisement

Table of Contents
loading

Table of Contents