Fujitsu PRIMERGY BX900 User Manual page 62

Blade server systems, serverview management blade s1, user interface description
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

Control via Tabs
You can specify the time delay (in minutes) which is to exist between powering on the system unit and powering
on the first server blade.
You can specify the time delay (in minutes) which is to exist between powering a server blade on/off and powering
the next server blade on/off.
You can choose between Graceful Shutdown And Power-Off and Hard Power-Off when powering off the server blades.
I
To permit graceful shutdown of a server blade, ServerView agents must have been installed and must be
active.
Figure 46: Power Management – Power Switch tab (4/4)
In the Power Restore Policy column you can choose between the values Always Power Off, Always Power On and
Restore to Power State Prior to Power Loss for each server blade which was not added to the Server Blade Power-On/Off
Sequence.
I
The Power Restore Policy is set to Always Power Off for all server blades which were not added to the Server
Blade Power-On/Off Sequence and cannot be changed.
A forced power-off can be enabled for each server blade in the fourth column in the table.
The time delay for a forced power-off after a normal power-off has failed can be set (in minutes) in the fifth column.
The table also provides information on other properties of the various server blades.