Heating Capacity Performance Data - Panasonic CS-F24DB4E5 Service Manual

Air conditioner
Hide thumbs Also See for CS-F24DB4E5:
Table of Contents

Advertisement

13.2. Heating Capacity Performance Data

Ambient
Model
Power
Return
(CS-)
Source
230V,
F24DB4E5
50Hz,
1 phase
230V,
50Hz,
F28DB4E5
1 phase
400V,
50Hz,
3 phase
230V,
F34DB4E5
50Hz,
1 phase
400V,
F34DB4E5
50Hz,
3 phase
400V,
F43DB4E5
50Hz,
3 phase
400V,
F50DB4E5
50Hz,
3 phase
HC: Heating Capacity
IPT: Heating Power Consumption
-6°C
Air
HC
IPT
D.B.
kW
kW
15
5.18
1.65
20
4.90
1.75
25
4.62
1.84
15
5.84
1.82
20
5.52
1.92
25
5.20
2.03
15
8.18
2.70
20
7.73
2.86
25
7.28
3.01
15
8.18
2.65
20
7.73
2.80
25
7.28
2.95
15
10.22
3.28
20
9.66
3.47
25
9.10
3.66
15
10.95
3.52
20
10.35
3.72
25
9.75
3.92
Temperature Air Entering Condenser (°C D.B.)
0°C
HC
IPT
HC
kW
kW
kW
6.21
1.89
7.46
5.86
2.01
7.10
5.54
2.12
6.75
7.00
2.08
8.40
6.60
2.21
8.00
6.24
2.34
7.60
9.80
3.09
11.76
9.24
3.28
11.20
8.74
3.47
10.64
9.80
3.02
11.76
9.24
3.21
11.20
8.74
3.40
10.64
12.25
3.75
14.70
11.55
3.99
14.00
10.92
4.22
13.30
13.13
4.02
15.75
12.38
4.28
15.00
11.70
4.53
14.25
114
6°C
12°C
IPT
HC
kW
kW
2.24
8.66
2.36
8.52
2.48
8.17
2.47
9.76
2.60
9.60
2.73
9.20
3.67
13.66
3.86
13.44
4.05
12.88
3.59
13.66
3.78
13.44
3.97
12.88
4.46
17.08
4.69
16.80
4.92
16.10
4.78
18.30
5.03
18.00
5.28
17.25
IPT
kW
2.64
2.74
2.80
2.91
3.02
3.05
4.32
4.48
4.57
4.23
4.38
4.48
5.25
5.44
5.56
5.63
5.83
5.96

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents