33 HEATING CAPACITY PERFORMANCE DATA

Model
Power
Source
(CS-)
External Static Pressure (Pa)
A24BB4P 230V,
50Hz,
Single phase
A28BB4P 230V,
50Hz,
Single phase
A34BB4P 230V,
50Hz,
Single phase
A34BB4P 400V,
50Hz,
Three phase
A43BB4P 400V,
50Hz,
Three phase
A50BB4P 400V,
50Hz,
Three phase
Legend:
H.C. = Heating Capacity
IPT = Power Consumption
Model
Heating capacities are based on conditions below.
CS-A24BB4P
1 phase, 50Hz, 230V
Heating capacity
Indoor temp. 20°C D.B.
7.1kW
Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 17 m
Model
Heating capacities are based on conditions below.
CS-A34BB4P
1 phase, 50Hz, 230V
Heating capacity
Indoor temp. 20°C D.B.
11.2kW
Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 27 m
Model
Heating capacities are based on conditions below.
CS-A43BB4P
3 phase, 50Hz, 400V
Heating capacity
Indoor temp. 20°C D.B.
14.0kW
Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 30 m
Inlet Air
3
Air Volume (m
/min)
17
18
27
27
30
31
3
/min
3
/min
3
/min
Entering Air
-6 °C
Dry Bulb (°C)
H.C.
IPT
15
5.18
1.74
20
4.90
1.84
25
4.62
1.94
15
5.84
1.92
20
5.52
2.03
25
5.20
2.14
15
8.18
2.49
20
7.73
2.63
25
7.28
2.77
15
8.18
2.38
20
7.73
2.52
25
7.28
2.65
15
10.2
2.87
20
9.66
3.03
25
9.10
3.20
15
11.3
3.48
20
10.70
3.68
25
10.08
3.88
Model
CS-A28BB4P
Heating capacity
8.0kW
Model
CS-A34BB4P
Heating capacity
11.2kW
Model
CS-A50BB4P
Heating capacity
15.5kW
151
Outdoor Temperature (°C W. B.)
0 °C
6 °C
H.C.
IPT
H.C.
6.21
1.99
7.46
2.37
5.86
2.12
7.10
2.49
5.54
2.24
6.75
2.61
7.00
2.19
8.40
2.60
6.60
2.33
8.00
2.74
6.24
2.47
7.60
2.88
9.80
2.84
11.8
3.37
9.24
3.02
11.2
3.55
8.74
3.20
10.6
3.73
9.80
2.72
11.8
3.23
9.24
2.89
11.2
3.40
8.74
3.06
10.6
3.57
12.3
3.28
14.7
3.90
11.6
3.49
14.0
4.10
10.9
3.69
13.3
4.31
13.6
3.98
16.3
4.72
12.8
4.22
15.5
4.97
12.1
4.47
14.7
5.22
Heating capacities are based on conditions below.
1 phase, 50Hz, 230V
Indoor temp. 20°C D.B.
Outdoor temp. 7°C D.B. 6°C W.B.
3
Standard air volume 18 m
/min
Heating capacities are based on conditions below.
3 phase, 50Hz, 400V
Indoor temp. 20°C D.B.
Outdoor temp. 7°C D.B. 6°C W.B.
3
Standard air volume 27 m
/min
Heating capacities are based on conditions below.
3 phase, 50Hz, 400V
Indoor temp. 20°C D.B.
Outdoor temp. 7°C D.B. 6°C W.B.
3
Standard air volume 31 m
/min
CASSETTE TYPE
12 °C
IPT
H.C.
IPT
8.66
2.79
8.52
2.89
8.17
2.95
9.76
3.07
9.60
3.18
9.20
3.22
13.7
3.98
13.4
4.12
12.9
4.30
13.7
3.81
13.4
3.94
12.9
4.07
17.1
4.59
16.8
5.00
16.1
5.60
18.9
5.57
18.6
6.06
17.8
6.60