4. Measure the distance between the ceiling and the upper unit base pan. If the divider is
not high enough, please fix the additional divider together by screws. The height can be
adjusted by the slotted holes until the divider is touching the base pan. See Figure 8
5. Cut the insulation to fit the divider. Remove paper backing and apply it to the divider,
make sure all gaps are sealed. Apply aluminum foil tape around all edges of insulation
See Figure 8
Figure 8
6. Connect 115VAC and 12VDC wires, Thermistor (Freeze Sensor), and thermostat cable
according to the wiring diagram. Install the cover over the electrical box using the small
screw provided. See Figure 9A and 9B
7. Install freeze sensor in center of evaporator coil between 2nd and 3rd line from bottom.
It should go into coil at a 45 degree downward angle. See Figure 10
Figure 10