Thermostat Wiring - Advent Roof Top Installation And Operating Instructions Manual

Roof top air conditioner ducted system
Table of Contents

Advertisement

THERMOSTAT WIRING

Function
12VDC input from main unit
DC Ground from main unit
Output to main unit
Output to main unit
Output to main unit
Output to main unit
Output to main unit
Input from main unit
IMPORTANT: When connecting the wires:
1. Make any adjustments required to relieve pinched or stressed wiring.
2. Verify that the connectors have snapped together on both sides. Do not use excessive
force when joining the connectors.
CONNECTING 115VAC WIRING
1. WARNING - SHOCK HAZARD: To prevent the possibility of severe personal injury or
equipment damage due to electrical shock, always be sure the electrical power is
disconnected or off before beginning installation.
2.
Route the 115 VAC supply wiring previously routed into the frame of the roof opening,
through the strain relief of the electrical box and into the high voltage wiring area
TO PREVENT THE POSSIBILITY OF SHOCK INJURY FROM APPLIANCE
OPERATION: THE WHITE WIRE MUST BE CONNECTED TO NEUTRAL IN THE
SERVICE BOX ENTRANCE AND THE MECHANICAL GROUND MUST BE
CONNECTED TO A GROUNDING LUG EITHER IN THE SERVICE BOX OR THE
MOTOR GENERATOR COMPARTMENT.
Wire Color
Red with White Stripe
Green
Yellow
White with Orange Stripe
Blue
Tan
Grey
Purple
DANGER
11
Label Text
"T-Stat Power (12VDC)
"T-Stat Trigger"
"Compressor"
Heat Trigger
"Hi Fan"
"Mid Fan"
"Low Fan"
Freeze Sensor
.