8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper
length.
8. Attach 6" x 10" (152mm x 254mm) duct to inner casing with (6)
#10 x 1/2" (13mm) screws provided.
9. Insert rear register into 8" x 12" (203mm x 305mm) boot. Attach
rear register to wall with (2) #10 x 1" (25mm) screws provided.
12428-7-1109
4" (102mm) MINIMUM
TO COMBUSTIBLES
WHEN SIDE
REGISTERS ARE
NOT USED UNIT
MAY BE RECESSED
4" (102mm)
3 1/4" (83mm)
11½" (292mm)
Locating Furnace On Wall
The furnace is to be located on a wall. The furnace is 16 inches (406mm)
in width and normal 16" (406mm) on center studs will not allow the fur-
nace to be recessed into the wall unless a stud is repositioned.
A template is proved in furnace carton for locating gas line connection.
Also, refer to Figure 2 for positioning the furnace on wall and for locating
gas line connection.
Locating Gas Supply
The gas line can enter the furnace either though the floor or wall. The gas
line opening should be made at this time. Location of the opening will be
determined by the position of floor joists and the valve and union used
for servicing.
Location Electric Supply
A 7/8" (22mm) diameter knockout is provided at the bottom of the left
and right side panels. A three-prong (grounding) plug assembly is located
within the control compartment (bottom) of the furnace. Please remove
7/8" (22mm) knockout from appropriate side panel when routing plug
assembly to an electrical outlet.
Installation of Three-prong (Grounding) Plug Assembly
1. Disconnect nylon cap on 3' (914mm) plug assembly from nylon plug
on wiring harness. Remove 3' (914mm) plug assembly from control
compartment (bottom) of the furnace.
2. Remove 7/8" (22mm) knockout from appropriate side panel.
3. Insert nylon cap on 3' (914mm) plug assembly into the 7/8" (22mm)
hole in the side panel.
4. Connect nylon cap on 3' (914mm) plug assembly to nylon plug on
the wiring harness.
5. Place 7/8" (22mm) strain relief bushing around the cord of the 3'
4" (102mm) MINIMUM
TO COMBUSTIBLES
5½"
(140mm)
5½"(140mm)
16" (406mm)
Page 5