OPtIONAL POSItIONING
OF tHERMOStAt
SENSING bULb
Continued
4. The mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capil-
lary at the bottom (see Figure 40). Slide the
thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Btu (Variable)
Type Gas
Ignition
Manifold Pressure
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
* For the purpose of input adjustment
Btu (Variable)
Type Gas
Ignition
Manifold Pressure
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
* For the purpose of input adjustment
30

SPEcIFIcAtIONS

18" Model
18" Model
(CGS2718PA)
(CLD3018PTA)
16,000/27,000
18,000/30,000
Propane/LP
Propane/LP
Piezo
Piezo
8.0" W.C.
8.0" W.C.
14"
14"
11"
11"
27 lbs.
27 lbs.
18" Model
18" Model
(CGS2718NA)
(CLD3018NTA)
16,000/27,000
18,000/30,000
Natural Gas
Natural Gas
Piezo
Piezo
3.5" W.C.
3.5" W.C.
10.5"
10.5"
5"
5"
27 lbs.
27 lbs.
www.desatech.com
Thermostat
Sensing Bulb
Capillary
Figure 40 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
24" Model
(CGS3124PA)
(SGS3124PA)
16,000/31,500
Propane/LP
Piezo
8.0" W.C.
14"
11"
29lbs.
24" Model
(CGS3124NA)
(SGS3124NA)
16,000/31,500
Natural Gas
Piezo
3.5" W.C.
10.5"
5"
29 lbs.
Adhesive-
backed
Mounting Clip
Do Not Crimp
Capillary
24" Model
(CLD3924PTB)
20,000/39,000
Propane/LP
Piezo
8.0" W.C.
14"
11"
27 lbs.
24" Model
(CLD3924NTB)
20,000/39,000
Natural Gas
Piezo
3.5" W.C.
10.5"
5"
29 lbs