Refrigeration Cycle Diagram - LG LS-J0762YL Service Manual

Room air conditioner
Hide thumbs Also See for LS-J0762YL:
Table of Contents

Advertisement

Refrigeration Cycle Diagram

INDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
MODEL
7k Btu Series(AC)
12k Btu Series(AC)
9k Btu Series(AC)
12k Btu Series(AC)
LIQUID SIDE
2-WAY VALVE
GAS SIDE
3-WAY VALVE
ACCUMU
LATOR
Pipe size(Diameter:Ø)
Gas(inch)
Liquid(inch)
3/8"
1/2"
3/8"
3/8"
-9-
OUTDOOR UNIT
CAPILLARY TUBE
COMPRESSOR
MAX.
Piping length
(m)
1/4"
15
1/4"
15
1/4"
15
1/4"
15
HEAT
EXCHANGE
(CONDENSER)
REVERSING
VALVE
(Heating Model Only)
COOLING
HEATING
Max
Elevation
(m)
7
7
7
7