64
Hardware Maintenance Manual
POST Error Code
962
Parallel port configuration error
9XX
1047
107X
Check SCSI terminator installation
1101
Serial connector error, possible system board
failure
1101, 1102, 1106, 1108, 1109
1107
1102
Card selected feedback error
1103
Port fails register check
1106
Serial option cannot be turned off
1107
1110
Register test failed
1116
Interrupt error
1117
Failed baud rate test
1162
Serial port configuration error
11XX
Not listed above
1201
1202, 1206, 1208, 1209, 12XX
FRU/Action
1. Run Configuration
2. Parallel Adapter (if installed)
3. System Board
1. Printer
2. System Board
1. 16-Bit AT
Fast SCSI Adapter
1. Check SCSI terminator installation
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1. Run Enhanced Diagnostics
1. System Board
2. Any Serial Device
1. Communications Cable
2. System Board
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
2. System Board
1. Run Enhanced Diagnostics
2. System Board
1. Serial Device Cable
2. System Board
1. Run Enhanced Diagnostics
2. System Board
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
1. System Board
1. System Board
2. Any Serial Device
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device