Information Menu

By gaining access to the Information Menu a number of values can be viewed. The information can be used to diagnose
faults, e.g. the value of a sensor to check if it is open circuit or closed circuit
Press 'ip' for 1 second.
The display will alternate between the '0'i code (e.g. i 02) and its value.
To scroll down the list press the 'ip' button.
i 00: Error Subcode See table on page 18
i 01: C.H. Temperature
i 02: External Temperature (if present)
i 03: D.H.W. Temperature
i 04: D.H.W. Temperature
i 05: Water Pressure
i 06: Return Temperature
i 07: Flue Temperature
i 08: Heat Exchanger Temperature
i 09: Not used
i 10: Not used
i 11: Not used
i 12: Not used
i 13: Not used
i 14: Not used
i 15: Not used
i 16 : Not used
i 17: Fan Speed RPM
i 18: num ic
This function operates for 3 minutes, or can be cancelled by pressing the reset 'R' button.
16
© Baxi Heating UK Ltd 2012
10.0 Information Menu
°C
°C
°C
i 03 & i 04 are the same sensor
°C
bar
°C
°C
°C
RPM