Empire Comfort Systems DVX36FP32CLN-2 Installation Instructions And Owner's Manual page 17

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

(305mm)
SEE CHART FOR
PERMISSIBLE
"H" AND "V"
DIMENSIONS
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOP OF FIREPLACE
Positioning the Fireplace
FIREPLACE
HARD ELBOW DIMENSIONS
SERIES
"A"
DVX36FP
43-1/2"
(1105mm)
DVX42FP
43-1/2"
(1105mm)
FIREPLACE
FLEX PIPE 90 DEGREE BEND
SERIES
"A"
DVX36FP
46"
(1143mm)
DVX42FP
46"
(1143mm)
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole (Figures 23)
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 12" (305mm) high x 10" (254mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination. See Figure 23. When locating the hole it must be noted
that the bottom of the cap must be 12" (305mm) above the ground
level, and top of the cap must be no less than 18" (457mm) below a
combustible projection, and no closer than 9" (229mm) to any wall
running parallel to vent termination. See Figure 24.
30329-0-0312
10"
(254mm)
C
12"
B
V
H
C
B
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
Figure 23
"B"
"C"
5"
7"
(127mm)
(178mm)
5"
7"
(127mm)
(178mm)
"B"
"C"
5"
7" (178mm)
(127mm)
5"
7"
(127mm)
(178mm)
Figure 24
Figure 25
Page 17