Optional Ak-4 Outside Air Kit - Monessen Hearth GCUF Installation And Operating Instructions Manual

Vent-free fireboxes
Table of Contents

Advertisement

COMBUSTION AIR
DO NOT remove the cover if the outside
air will not be connected.
The use of outside air for combustion is optional unless
required by building codes. It is only necessary to supply
outside combustion air to one side of the fireplace. Use the
model AK4 combustion air kit.
MODEL Ak-4 COMBUSTION AIR ASSEMBLY
1. Remove the cover plate from the 4" outlet opening loca-
tion on the left or right outside of the fireplace.
. Place the insulation ring between the AK-4 starting collar
and fireplace wall.
3. Place the starting collar (4") into the hole on the side
of fireplace. Fasten it in place with the four sheet metal
screws provided. Figures 16 and 17
NOTE: The air starting collar extends through the
fireplace outer wrap. When the air starting collar
is securely attached, it will form a seal against the
fireplace wall.
Insulation
Ring
Shorter End
of Air Starting
Collar
Left Side of
Fireplace
Figure 16 -
Attach Outside Air Starting Collar and Insulation
Ring to Left Side of Fireplace
FP1900
OA start collar
Use Fp-4 U duct for maximum efficiency
8/08
and safety. Do not use a combustible duct.
Always use UL Listed Class 0 or 1 duct
material.
71D0530
Sheet Meal
AK-4 Starting
Screws
Collar
Air Starting
Collar
FP700
Figure 17 -
Attach Outside Duct to Starting Collar
FP2700
4. Attach outside duct to starting collar with duct clamp or
OA duct
screws. Figure 17
5. Cut a 6-inch diameter opening for model AK-4 in the
outside wall covering where the outside vent is to be
located. Figure 18
6. Select and cut a piece of duct long enough to attach to
the fireplace and stick out at least 3" beyond the face of
the wall to which the AK-4 inlet air vent will be attached.
Cut duct with a standard pocket knife. Figure 17
6"
Diameter
Hole
Duct
Extending
3" Min.
FP1904
Figure 18 -
Combustion Air Assembly for Model
AK-4
GCUF Vent-Free Fireboxes
Screws
Duct
Left Side of
Fireplace
Screws
AK-4 Inlet
Air Vent
FP1904
AK4 install
8/08
Nail
Hole
Screws