  • Page 1 Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Model: CL25AE For product enquiry or support contact: E-mail: kas.inquiry@khindmistral.com Power rating: 235 Watts Customer Service Hotline: 1300 8000 32 Voltage rating: 220-240 Volt AC, 50Hz www.honeywellaircoolers.com...
  • Page 2: Quick Start Guide

    QUICK START GUIDE Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze.
  • Page 3: Table Of Contents

    INDEX Read all instructions carefully before setting up and operating the cooler, and keep this instruction manual for future reference. This manual is designed to provide you with impor- tant information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.
  • Page 4: Thank You

    THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler.
  • Page 5: User Tips

    USER TIPS Energy efficient, No compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air.
  • Page 6 USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces.
  • Page 7: Safety

    SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: Your cooler runs on 220~240 Volts, 50 Hz current. Check the • household voltage to ensure it matches the appliance's rate speci- 220~240 Volt AC 50Hz fication.
  • Page 8 SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. •...
  • Page 9: Parts Description

    PARTS DESCRIPTION 1 Control Panel 8 Vertical Louvers 2 Side Handle (Automatic Movement with SWING) 3 Horizontal Louvers 9 Front Panel (Manual Adjustment) 10 Water Level Indicator 4 Left Side Panel 11 Remote Control 5 Power Cord & Plug 12 Remote Control Holder 6 Castors 13 Water Tank 7 Ice Compartment Lid...
  • Page 10: Use & Operation

    USE & OPERATION CONTROL PANEL POWER Tank Empty...
  • Page 11: Function Buttons

    USE & OPERATION Function Buttons POWER Press the POWER button to turn the unit on. To turn the unit off, press the button again. The cooler will start automatically POWER at medium speed. After a few seconds the speed will switch Tank Empty to low.
  • Page 12: Low Water Alarm Function

    USE & OPERATION SWING / ION To switch between the SWING, ION & SWING+ION modes. Press the SWING button. The indicator light on 'S' will come on and the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow.
  • Page 13: Room Cooling And Humidifying

    USE & OPERATION ROOM COOLING AND HUMIDIFYING When the water regulator is set to MIN, the water pump Water Regulator distributes a minimal amount of water to the honeycomb media. This results in less water evaporation and reduces cooling effect. Thus, reducing the humidity inside the room. When the water regulator is set to MAX, the water pump distributes the maximum amount of water to the honeycomb media.
  • Page 14: Remote Control

    USE & OPERATION REMOTE CONTROL Power: On/ Off Speed: Low / Medium / High / Sleep POWER Mode : Controls cooling or fan option Swing / Ion : Controls the motion of the vertical louvers and Ionizer function Timer: Set the unit to turn off automatically after SWING SPEED desired number of hours.
  • Page 15: Filling Water

    USE & OPERATION FILLING WATER The water tank of the unit holds up to 25 litres of water. Water needs to be filled inside the unit with the help of water fill door located on the left side panel of the unit. You may use a water filled jug to manually fill water inside the tank or can also connect a water pipe to fill this tank.
  • Page 16: Cleaning & Maintenance

    CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the off position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use detergents, corrosive elements or any chemicals to clean this product. •...
  • Page 17 CLEANING & MAINTENANCE CLEANING THE CARBON / DUST FILTER • Turn off the unit, and unplug the power cord from wall outlet. Knobs • Rotate the unit facing the back panel, and locate the knobs to remove back grill. • Press both the knobs (see fig.) and gently pull out the back grill, untill it is completely removed.
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Supply switch in ON. Power is not ON. Turn the unit ON by pressing buttons on the control panel or remote control. Not Cooling / Unit is Pump is not turned ON.
  • Page 19 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION The unit does not respond Remote control batteries. Check batteries, Replace if to remote control needed. Try to operate using the control panel. Try to activate the unit with the Damaged Control Panel Remote Control. If the unit on unit.
  • Page 20: Technical Specifications

    TECHNICAL SPECIFICATIONS MODEL NO. CL25AE Voltage 220~240V 50Hz Frequency 235 Watts Wattage Water Tank Capacity 25 Litre Cooling Media Honeycomb Product Dimension 480 (W) x 370 (D) x 847 (H) mm 11.5 Kg Net Weight ELECTRICAL WIRING DIAGRAM Ionizer Water pump Sync.
  • Page 21 Sole distributor: © 2013, AirTek Int’l Corp. Ltd. Khind Alliances Sdn Bhd (JMATEK Int’l Group of Companies) The Honeywell Trademark is used under license from ( formerly known as Indesico (M) Sdn Bhd ) Honeywell International Inc. E-mail: kas.inquiry@khindmistral.com Honeywell International Inc. makes no representation or Customer Service Hotline: 1300 8000 32 warranties with respect to this product.

Table of Contents