Carrier 38BYG Product Data page 27

60 hz 12 seer sizes 018 thru 060
Table of Contents

Advertisement

Heat pump heating performance continued
–3
INDOOR
Capacity
Total
Capacity
AIR
MBtuh
Power
EDB CFM Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW†
38BYG030-30 Outdoor Section With F(A,B)4BN(F,C)036 Indoor Section
875
12.2
11.2
2.00
15.0
65
1000
12.4
11.4
2.02
15.2
1125
12.6
11.6
2.05
15.4
875
11.9
10.9
2.08
14.7
70
1000
12.1
11.1
2.11
15.0
1125
12.3
11.3
2.14
15.2
875
11.6
10.7
2.16
14.5
75
1000
11.8
10.9
2.19
14.7
1125
12.0
11.0
2.22
14.9
Indoor
Section
Size
CC5A/CD5AA
030
036
CC5A/CD5AW
030
036
CE3AA
030
036
CF5AA
036
CK3BA
030
036
CK5A/CK5BA
036
CK5A/CK5BT
036
CK5A/CK5BW
030
036
F(A,B)4BN(F,C)
030
036
FC4CNF
030
036
FF1DNA
030
FF1DNE
030
FG3AAA
036
FK4DNF
001
002
003
COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE
CC5A/CD5AA
036
CE3AA
036
CK3BA
036
CK5A/CK5BA
036
CK5A/CK5BT
036
See notes on pg. 33.
OUTDOOR COIL ENTERING AIR TEMPERATURES
7
17
Total
Capacity
Total
MBtuh
Power
MBtuh
Power
13.8
2.07
18.1
16.5
2.15
14.0
2.09
18.4
16.8
2.16
14.2
2.11
18.6
17.0
2.18
13.5
2.16
17.8
16.3
2.25
13.8
2.18
18.1
16.5
2.25
13.9
2.20
18.3
16.7
2.27
13.3
2.26
17.6
16.0
2.35
13.5
2.27
17.8
16.2
2.35
13.7
2.30
18.0
16.5
2.37
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
0.98
1.04
0.99
0.98
0.98
1.04
0.99
0.98
0.99
0.99
0.99
1.01
0.99
0.99
0.98
1.00
0.99
0.97
0.99
0.98
0.99
0.97
0.98
1.00
0.99
0.97
0.99
0.98
1.00
1.00
0.99
0.98
1.00
1.01
0.99
0.98
0.99
0.98
0.99
1.00
0.98
0.95
0.98
0.92
0.97
0.92
0.98
0.96
0.98
0.98
0.98
0.93
0.98
0.93
0.98
0.93
27
37
Capacity
Total
Capacity
Total
MBtuh
Power
MBtuh
Power
21.6
19.2
2.26
25.4
23.1
2.39
21.9
19.4
2.26
25.7
23.4
2.38
22.1
19.7
2.27
26.0
23.6
2.38
21.3
18.9
2.36
25.1
22.9
2.50
21.6
19.2
2.36
25.4
23.1
2.48
21.9
19.4
2.37
25.7
23.4
2.49
21.0
18.7
2.47
24.8
22.6
2.61
21.3
18.9
2.46
25.1
22.9
2.59
21.5
19.1
2.47
25.4
23.1
2.60
Indoor
Section
COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BW
COILS + 58MVP060-14 VARIABLE-SPEED FURNACE
CC5A/CD5AA
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
COILS + 58MVP080-14 VARIABLE-SPEED FURNACE
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BW
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
CC5A/CD5AW
CE3AA
CK5A/CK5BW
°
F
47
57
Capacity
Total
Capacity
Total
MBtuh
Power
MBtuh
Power
29.6
29.6
2.55
34.5
34.5
2.77
30.0
30.0
2.54
34.6
34.6
2.69
30.2
30.2
2.53
34.4
34.4
2.65
29.3
29.3
2.67
34.1
34.1
2.89
29.6
29.6
2.65
34.4
34.4
2.83
29.9
29.9
2.64
34.4
34.4
2.78
28.9
28.9
2.79
33.7
33.7
3.02
29.3
29.3
2.76
34.1
34.1
2.98
29.5
29.5
2.76
34.3
34.3
2.93
Heating
Size
Capacity
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
036
0.98
67
Capacity
Total
MBtuh
Power
39.0
39.0
2.91
38.4
38.4
2.83
37.8
37.8
2.78
38.9
38.9
3.07
38.6
38.6
2.97
38.1
38.1
2.92
38.7
38.7
3.23
38.6
38.6
3.12
38.2
38.2
3.07
Power
0.95
0.95
0.97
0.93
0.93
0.93
0.94
0.97
0.93
0.93
0.93
0.93
0.96
0.92
0.92
0.93
0.93
0.96
0.91
0.91
0.91
0.91
0.93
0.96
0.91
27