INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
HD35NT, HD40NT
& HD46NT

NATURAL GAS

HD35PT, HD40PT
& HD46PT
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleon.on.ca
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
C E R T I F I E D
1.1
W415-0820 / B / 10.23.09
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon HD35NT

  • Page 1: Natural Gas

    INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS. HD35NT, HD40NT & HD46NT NATURAL GAS HD35PT, HD40PT & HD46PT PROPANE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW USING NON-COMBUSTIBLE MATERIAL USING COMBUSTIBLE MATERIAL INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION CARE OF GLASS CARE OF PLATED PARTS VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION 3.3.2 CORNER TERMINATION VENT TERMINAL CLEARANCES...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW USING NON-COMBUSTIBLE MATERIAL FIGURE 1.1 Mantel, see “MINIMUM MANTEL CLEAR- ANCES” section. Enclosures, see the section “MINIMUM CLEARANCES TO COMBUSTIBLE Venting, see “VENTING” ENCLOSURES” section. section for drywall (or other combustible material). Framing, see “FRAMING” section. Enclosures, see the section “MINIMUM CLEARANCE TO COM- BUSTIBLE ENCLO-...
  • Page 4: Using Combustible Material

    USING COMBUSTIBLE MATERIAL FIGURE 1.2 Mantel, see “MINI- MUM MANTEL CLEARANCES” section. Enclosures, see “MINIMUM CLEARANCE TO COM- BUSTIBLE ENCLO- SURES” for drywall (or Venting, see “VENTING” other combustible mate- section. rial)” section. Framing, see “FRAMING” section. Framing, see “FRAMING” section Side Wall...
  • Page 5: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury. •...
  • Page 6: Dimensions

    DIMENSIONS HD35 HD40 HD46 41” 41” 41” 3” 3” 3” 39 1/4” 39 1/4” 39 1/4” 38” 38” 38” 10 3/16” 10 3/16” 10 3/16” 35 1/4” 40 1/4” 46 1/4” 23” 28” 34” 20” 20” 20” 20 1/2” 20 1/2” 20 1/2”...
  • Page 7: General Instructions

    GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”...
  • Page 8: General Information

    Air shutter Control Input Input setting Natural Propane BTU/h BTU/h Minimum Inlet 4.5” w.c. 11.0” w.c. HD35NT Nat IPI Hi/Lo 25,000 17,500 1/8” Open Maximum Inlet 7.0” w.c. 13.0” w.c. HD35PT Prop* IPI Hi/Lo 25,000 17,500 5/16” Open Manifold Pressure 3.5”...
  • Page 9: Rating Plate Information

    RATING PLATE INFORMATION CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / APPAREIL DE CHAUFFAGE À GAZ VENTILÉS. APPAREIL DE CHAUFFAGE À ÉVACUATION DIRECTE. HOMOLOGUÉ POUR INSTALLATION DIRECT VENT GAS FIREPLACE HEATER. SUITABLE FOR BEDROOM, BATHROOM AND DANS UNE CHAMBRE À...
  • Page 10: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 11: Typical Vent Installations

    For optimum flame appearance and appliance performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Rigid and fl...
  • Page 12: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” above grade. The maximum allowable vent length is 10’. 12”...
  • Page 13: Vent Terminal Clearances

    VENT TERMINAL CLEARANCES FIGURE 3.4 INSTALLATIONS CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. 12” 9” Clearance to windows or doors that open. 12” * 12” * Clearance to permanently closed windows. Vertical clearance to ventilated soffi ts located above the terminal within a horizontal distance of 2’ from 18”...
  • Page 14: Vent Application Flow Chart

    VENT APPLICATION FLOW CHART Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run + Horizontal run +...
  • Page 15: Horizontal Termination

    HORIZONTAL TERMINATION ) < (V Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H REQUIRED FIGURE 3.8.1 VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 16 ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 147” REQUIRED VERTICAL FIGURE 3.8.3 RISE IN INCHES V 57” 19 1/2” 2’ 12.5’ 19.5’ HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 17: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H FIGURE 3.9.1 REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring one or more 90°...
  • Page 18 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H FIGURE 3.9.3 REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring more than two 90°...
  • Page 19: Installation

    4.0 INSTALLATION WARNING FOLLOW THE VENTING INSTRUCTIONS EXACTLY. ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC.
  • Page 20: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 21: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 22: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 23: Using Rigid Vent Components

    USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel Ltd. support ring assembly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs. All inner exhaust and outer intake vent pipe joints may be sealed using either red high temperature silicone sealant W573-0002 (not supplied) or black high temperature sealant W573-0007 Mill Pac (not supplied) with the exception of the appliance exhaust fl...
  • Page 24: Vertical Venting Installation

    4.3.3 VERTICAL VENTING INSTALLATION Move the appliance into position. INNER PIPE Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority FIGURE 4.3.3e having jurisdiction or the optional roof support.
  • Page 25: Mobile Home

    MOBILE HOME This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 26: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 27: Framing

    5.0 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLI- ANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 28 FIGURE 5.0 WARNING DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR THE VENT IN THIS 14” WIDE AREA CENTERED ALONG THE FRONT OF THE APPLIANCE. NO COMBUSTIBLES ARE ALLOWED. 3 1/2” MAX NOTE: Three braces are required (as nailers) if using optional 4-sided frame kit.
  • Page 29: Minimum Clearance To Combustibles

    MINIMUM CLEARANCE TO COMBUSTIBLES COMBUSTIBLE FRAMING: Sides, back, bottom and top 0” to stand-offs of the appliance COMBUSTIBLE FINISHING: Sides, Bottom and Top 0” to front edge of the appliance Enclosure Top 70” from the bottom of the appliance Recessed Depth 20”...
  • Page 30: Minimum Clearance To Combustible Enclosures

    MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES NON-COMBUSTIBLE FIGURE 5.2a COMBUSTIBLE BRICK 0” IF NON- COMBUSTIBLE FINISH- 2” ING IS USED SUCH AS 9” BRICK AND STONE WOOD HEADER 32” 1” 4” 6 1/2”** 70” NON- 57 1/2” COMBUSTIBLE MINIMUM MATERIAL PLUS RISE* FRONT HOOD 38”...
  • Page 31 NON-COMBUSTIBLE FINISHING MATERIAL COMBUSTIBLE FINISHING MATERIAL FIGURE 5.2b FIGURE 5.2c COMBUSTIBLE MATERIAL NON-COMBUSTIBLE COMBUSTIBLE REQUIRED IF USING MATERIAL OPTIONAL 4-SIDED FRAME KIT NON- COMBUSTIBLE MATERIAL SUCH AS TILE, MARBLE, GRANITE, ETC. 12” 2” 6 1/2” 7 3/8” MIN. NON-COMBUSTIBLE REQUIRED 1 1/4”...
  • Page 32: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 33: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. AS AN ALTERNATIVE, YOU CAN FINISH THE APPLIANCE WITH DRYWALL, SEE ILLUSTRATIONS TO FOLLOW.
  • Page 34: Door Glass Replacement

    DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 35: Log Placement

    LOG PLACEMENT WARNING LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT CHANGE OR MODIFY FROM THE PROPER LOG POSITION, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR. THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. The individual logs can be easily identifi...
  • Page 36 FIGURE 6.3.4 6.3.4 Place the right log (W135-0407) on top of the middle log by locat- ing the bottom rectangular holes of the right log onto the knob of the middle log. The end of the log with a cut out notch will seat against the back of the right end front grate post.
  • Page 37: Glowing Ember Placement

    GLOWING EMBER PLACEMENT Tear the embers into pieces and place on top of the front burner area be- FIGURE 6.4 tween the middle log and charcoal strip. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the #4 GLOWING EMBERS #4 GLOWING EMBERS fi...
  • Page 38: Optional Blower Installation

    7.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 39: Installing The Blower

    INSTALLING THE BLOWER FIGURE 7.2.1a Installation to be done by a qualifi ed installer and must be electrically con- nected and grounded in accordance with local codes. In the absence of lo- cal codes, use the current CSA C22.1 Canadian Electrical Code in Cana- da or the ANSI / NFPA 70 National Electrical Code in the United States.
  • Page 40: Wiring Diagram / Electrical Information

    8.0 WIRING DIAGRAM / ELECTRICAL INFORMATION WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
  • Page 41: Junction Box Installation

    JUNCTION BOX INSTALLATION 8.3.1 Remove the two screws that secure the junction box assembly to the outer shell on the left side of the fi re place and remove the junction box assembly. 8.3.2 Remove the one screw that secures the junction box to the junction box plate and slide off the clip.
  • Page 42: Wiring Diagram

    WIRING DIAGRAM WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. A wall switch must be installed in a convenient location for the burner operation. The recommended maximum lead length depends on the wire size: WIRE SIZE MAX.
  • Page 43: Operation

    9.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 44: Adjustment

    10.0 ADJUSTMENT 10.1 PRESSURE ADJUSTMENT Inlet pressure can be checked by turning screw (A) counter-clockwise until loosened and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 13” (11” minimum) water column for propane. Check that main burner is operating on “HI”.
  • Page 45: Flame Characteristics

    10.4 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ames appear abnor- mal call a service person. FIGURE 10.4a 54.3 FIGURE 10.4b FIGURE 10.4c HD46 HD35 / HD40...
  • Page 46: Replacement Parts

    12.0 REPLACEMENT PARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 47 ACCESSORIES REF HD35 PART NO. HD40 PART NO. HD46 PART NO. DESCRIPTION W573-0007 W573-0007 W573-0007 10.3 OZ TUBE HIGH TEMP SEALANT MILPAC GZ550-1KT GZ550-1KT GZ550-1KT BLOWER KIT B440-KT B440-KT B440-KT BLOWER KIT W500-0033 W500-0033 W500-0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE W690-0005 W690-0005 W690-0005...
  • Page 48 ROOF TERMINAL KITS REF HD35 PART NO. HD40 PART NO. HD46 PART NO. DESCRIPTION GD-110 GD-110 GD-110 1/12 TO 7/12 PITCH GD-111 GD-111 GD-111 8/12 TO 12/12 PITCH GD-112 GD-112 GD-112 FLAT ROOF W490-0073 W490-0073 W490-0073 4/7 INNER/OUTER SLEEVE W670-0006 W670-0006 W670-0006 4/7 TERMINAL...
  • Page 49: Troubleshooting

    13.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 50 SYMPTOM PROBLEM TEST SOLUTION Continues to Short or loose Verify all connections. Verify the connections from the pilot spark and pilot connection in sensor assembly are tight; also verify these connections are not lights, but main rod. grounding out to any metal. burner will not Verify the TH wires are connected to the valve.
  • Page 51: Warranty

    14.0 WARRANTY NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station.
  • Page 52: Service History

    15.0 SERVICE HISTORY 43.1 W415-0820 / B / 10.23.09...