Power Spot 700™
until internal temperature drops below 95˚C. Outside surface temperature
should not exceed 45˚C.
3.9.7 Fan Control
FANS
By using this function you can choose between 4 types of fan speed
operations. Use the Up and Down buttons to select the desired fan setting,
then press Enter to accept your setting or press the Mode button to cancel
and return to the menu. The chart below will detail the different fan settings:
HIGH
REG
LOO
F
LOHI
3.9.8 Adjustments and Calibrations
ADJU
With this function you can adjust and calibrate the positions of the different
wheels and other motors. This feature is reserved for a service technician and
is sometimes required after a service or repair work.
This function requires a service code only available to authorized service
technicians.
©Elation Professionals® Los Angeles, Ca.
The cooling fan works continuously at max. speed.
This is the default fan setting. In this setting an internal thermal
sensor constantly monitors the internal operating temperature
and regulates the fan speed to coincide with the internal
temperature.
This function is designed for environments that require low
ambient noise. In this setting the fan will operate at the lowest
speed. When the maximum internal intolerable operating
temperature is reached the lamp will automatically shut off.
In this setting the fan will operate at the lowest speed. When the
maximum internal intolerable operating temperature is reached
the fan will automatically switch from low to high speed.
-