Performance data (cont)
ACTUAL
AIRFLOW
02
(Cfm)
TH
SH
100
0.62
0.57
125
0.72
0.69
150
0.82
0.80
175
0.92
0.91
200
1.00
1.00
225
1.08
1.08
250
1.16
1.18
275
—
—
300
—
—
350
—
—
400
—
—
450
—
—
500
—
—
550
—
—
600
—
—
700
—
—
800
—
—
900
—
—
1000
—
—
1200
—
—
1400
—
—
LEGEND
SH — Sensible Heat
TH — Total Heat
NOTE: Use Sensible Heat correction factors when calculating heating capacity.
SAT
UNIT
SUCT
SIZE
TEMP
76/63
(F)
TH
SH
35
7.3
40
5.7
02
45
4.3
50
3.1
35
10.5
40
8.4
03
45
6.3
50
4.7
35
14.1
10.4
40
11.6
04
45
8.9
50
6.6
35
19.0
14.5
40
15.2
12.7
06
45
11.6
11.0
50
8.7
35
24.6
18.8
40
20.1
16.8
08
45
15.6
14.7
50
11.9
11.9
35
29.9
23.3
40
24.7
21.0
10
45
19.3
18.4
50
14.8
14.8
35
40.3
30.0
40
32.7
26.4
12
45
24.9
22.9
50
18.6
18.6
LEGEND
db — Dry Bulb
SH — Sensible Heat
TH — Total Heat
wb — Wet Bulb
*Capacity based on R-22. Ratings at nominal cfm. All DX units to operate at high speed only.
60
COOLING CAPACITY CORRECTION FACTORS
03
04
TH
SH
TH
SH
—
—
—
—
0.54
0.48
0.44
0.39
0.62
0.57
0.51
0.45
0.69
0.65
0.57
0.50
0.76
0.73
0.62
0.57
0.82
0.80
0.67
0.63
0.89
0.87
0.72
0.69
0.95
0.94
0.77
0.74
1.00
1.00
0.82
0.80
1.11
1.12
0.92
0.91
—
—
1.00
1.00
—
—
1.08
1.08
—
—
1.16
1.18
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
DIRECT-EXPANSION (DX) COIL COOLING CAPACITIES (MBtuh)* —
MODELS 42CA,CE,CF,CG,CK
3 ROW
78/65
80/67
TH
SH
TH
5.4
8.1
5.7
9.0
4.7
6.6
4.9
7.4
4.0
4.9
4.2
5.7
3.1
3.6
3.5
4.1
7.8
11.6
8.1
12.8
6.8
9.5
7.1
10.7
5.8
7.3
6.2
8.5
4.7
5.4
5.2
6.2
15.5
10.8
16.9
11.1
9.2
13.0
9.6
14.5
10.0
8.0
10.2
8.4
11.7
6.6
7.6
7.2
8.8
21.0
15.0
23.1
15.6
17.3
13.3
19.4
13.9
13.3
11.6
15.2
12.2
8.7
9.9
9.8
11.2
10.5
27.0
19.4
29.4
20.0
22.6
17.5
25.2
18.2
17.8
15.4
20.3
16.2
13.4
13.2
15.3
14.0
32.7
24.0
35.6
24.7
27.7
21.8
30.7
22.6
22.0
19.3
24.9
20.2
16.7
16.6
19.0
17.6
44.4
31.1
48.7
32.2
36.9
27.7
41.2
28.9
28.6
24.1
32.9
25.4
21.2
20.6
24.4
21.9
UNIT SIZE
06
08
TH
SH
TH
SH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.46
0.41
—
—
0.51
0.45
—
—
0.55
0.49
—
—
0.58
0.53
0.47
0.42
0.62
0.57
0.51
0.45
0.69
0.65
0.57
0.50
0.76
0.73
0.62
0.57
0.82
0.80
0.67
0.63
0.89
0.87
0.72
0.69
0.95
0.94
0.77
0.74
1.00
1.00
0.82
0.80
1.11
1.12
0.92
0.91
—
—
1.00
1.00
—
—
1.08
1.08
—
—
1.16
1.18
—
—
—
—
—
—
—
—
Entering Air (F) — db/wb
82/69
76/63
SH
TH
SH
TH
5.9
9.9
6.1
9.0
5.2
8.3
5.4
7.3
4.5
6.6
4.7
5.6
3.8
4.5
4.0
4.1
8.4
14.0
8.7
12.7
7.5
11.9
7.8
10.5
6.5
9.7
6.8
8.1
5.6
7.2
5.9
6.0
18.4
11.5
16.4
16.0
10.4
13.8
8.9
13.2
9.3
10.9
7.7
10.2
8.1
8.2
25.3
16.1
23.3
21.6
14.5
19.3
17.4
12.8
15.0
13.0
11.1
10.9
31.9
20.6
29.1
27.8
18.9
24.6
23.0
16.9
19.6
17.6
14.8
14.6
38.5
25.3
35.2
33.8
23.3
30.0
28.1
21.0
24.1
21.8
18.6
18.2
53.1
33.3
48.2
45.7
30.0
40.2
37.4
26.6
31.5
28.4
23.1
23.5
10
12
TH
SH
TH
SH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.43
0.38
—
—
0.48
0.46
—
—
0.53
0.47
0.46
0.41
0.58
0.52
0.51
0.45
0.62
0.57
0.55
0.47
0.66
0.62
0.58
0.53
0.70
0.67
0.62
0.57
0.78
0.76
0.69
0.65
0.86
0.85
0.76
0.73
0.94
0.93
0.82
0.80
1.00
1.00
0.89
0.87
1.13
1.14
1.00
1.00
—
—
1.11
1.12
4 ROW
78/65
80/67
SH
TH
SH
TH
6.4
10.0
6.7
11.0
5.6
8.3
5.9
9.3
4.8
6.4
5.1
7.4
4.0
4.7
4.3
5.5
9.1
14.0
9.5
15.3
8.1
11.8
8.5
13.1
7.0
9.3
7.4
10.7
6.0
6.9
6.3
8.1
11.9
17.9
12.3
19.4
10.7
15.4
11.1
17.0
9.4
12.5
9.8
14.2
8.0
9.4
8.5
11.0
17.1
25.6
17.7
27.9
15.2
21.6
15.9
24.0
13.3
17.1
14.0
19.6
10.9
12.8
12.0
14.8
21.8
31.7
22.5
34.3
19.7
27.4
20.5
30.1
17.4
22.2
18.3
25.1
14.6
17.0
15.9
19.5
26.9
38.3
27.6
41.3
24.5
33.3
25.4
36.6
21.8
27.3
22.8
30.7
18.2
21.1
19.9
24.1
35.0
52.7
36.2
57.4
31.2
44.9
32.6
49.8
27.2
36.1
28.7
41.0
23.1
26.9
24.7
31.3
82/69
SH
TH
SH
7.0
12.1
7.3
6.2
10.3
6.5
5.4
8.5
5.7
4.6
6.4
4.9
9.8
16.6
10.2
8.8
14.5
9.2
7.8
12.1
8.1
6.7
9.4
7.1
12.7
21.0
13.0
11.5
18.6
11.9
10.3
15.8
10.8
9.0
12.7
9.5
18.3
30.3
18.9
16.6
26.5
17.2
14.7
22.1
15.3
12.7
17.1
13.4
23.1
37.0
23.6
21.2
33.0
21.8
19.1
28.1
19.8
16.8
22.4
17.6
28.2
44.4
28.8
26.2
39.9
26.9
23.7
34.3
24.6
21.0
27.5
22.0
37.4
62.2
38.5
33.9
54.7
35.1
30.1
46.1
31.4
26.1
36.3
27.5