System Design - Carrier 38AYC Product Data

11 seer 60 hz sizes 018 thru 060
Hide thumbs Also See for 38AYC:
Table of Contents

Advertisement

Heat pump heating performance continued
–3
INDOOR
Capacity
Total
Capacity
AIR
MBtuh†
Power
EDB
CFM Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW†
38AYC060-33, 34 Outdoor Section With FB4BNB070 Indoor Section
1750 28.6 26.3 4.31 33.8 31.0 4.48 39.4 35.9 4.65 45.5 40.4 4.85 52.6 47.9 5.09 60.7 60.7 5.38 70.0 70.0 5.76 80.7 80.7 6.25
65
2000 29.1 26.7 4.37 34.2 31.4 4.52 39.9 36.3 4.68 46.0 40.8 4.85 53.2 48.4 5.07 61.4 61.4 5.34 71.5 71.5 5.71 81.4 81.4 6.12
2250 29.5 27.1 4.44 34.6 31.8 4.57 40.3 36.7 4.72 46.5 41.3 4.88 53.7 48.9 5.08 62.0 62.0 5.35 71.6 71.6 5.71 81.1 81.1 6.02
1750 28.2 25.9 4.48 33.5 30.8 4.68 39.0 35.6 4.87 45.0 40.0 5.08 52.0 47.4 5.33 60.0 60.0 5.63 69.2 69.2 6.03 79.7 79.7 6.53
70
2000 28.6 26.3 4.54 33.9 31.2 4.72 39.5 36.0 4.89 45.6 40.5 5.08 52.7 47.9 5.31 60.7 60.7 5.59 70.1 70.1 5.96 80.7 80.7 6.46
2250 29.1 26.7 4.61 34.3 31.5 4.78 39.9 36.4 4.94 46.0 40.9 5.11 53.2 48.4 5.32 61.3 61.3 5.59 70.7 70.7 5.95 81.0 81.0 6.33
1750 27.6 25.4 4.67 33.2 30.5 4.89 38.7 35.3 5.10 44.6 39.6 5.32 51.5 46.9 5.59 59.3 59.3 5.90 68.4 68.4 6.30 78.7 78.7 6.82
75
2000 28.1 25.8 4.72 33.6 30.9 4.93 39.2 35.7 5.12 45.1 40.1 5.32 52.2 47.5 5.56 60.1 60.1 5.85 69.3 69.3 6.23 79.8 79.8 6.74
2250 28.5 26.3 4.79 34.0 31.3 4.99 39.6 36.1 5.16 45.6 40.5 5.34 52.7 47.9 5.57 60.6 60.6 5.84 70.0 70.0 6.21 80.5 80.5 6.70
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
F(A,B)4BN(F,B,C)
060
FB4BNB
070
FC4CN(F,B)
060
FC4CNB
070
FG3AAA
060
FK4DNB
006
COILS + 58CV(A,X)110-22 FURNACE
CC5A/CD5AA
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from sup-
plement heaters should be added to those values to obtain total system capacity.
† The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these
values to obtain total system kilowatts.
EDB – Entering Dry-Bulb

System Design

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C).
4. Minimum outdoor operating air temperature for heating mode is –30°F (–34.4°C).
5. Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C).
6. For reliable operation, unit should be level in all horizontal planes.
7. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft.
8. For interconnecting refrigerant tube lengths greater than 50 ft horizontal or 20 ft vertical differential, consult Residential Split-System Long-Line
Application Guideline available from equipment distributor.
9. For more than 36 in. of refrigerant tubing buried in the ground, consult your local distributor.
10. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
11. Mismatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Total
Capacity
Total
MBtuh†
Power
MBtuh†
Power
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
27
37
Capacity
Total
Capacity
Total
MBtuh†
Power
MBtuh†
Power
Indoor
Section
1.13
CK5A/CK5BT
1.04
CK5A/CK5BX
1.04
1.08
CC5A/CD5AA
1.08
CC5A/CD5AW
1.08
CE3AA
1.04
CK3BA
1.04
CK5A/CK5BA
1.00
CK5A/CK5BT
1.04
CK5A/CK5BX
1.01
1.06
CC5A/CD5AA
0.97
CC5A/CD5AW
CE3AA
1.14
CK3BA
1.06
CK5A/CK5BA
1.03
CK5A/CK5BT
1.03
CK5A/CK5BX
47
57
Capacity
Total
Capacity
MBtuh†
Power
MBtuh†
Size
Capacity
060
1.00
060
1.00
COILS + 58CV(A,X)135-22 FURNACE
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
COILS + 58CV(A,X)155-22 FURNACE
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
060
1.00
67
Total
Capacity
Total
Power
MBtuh†
Power
Heating
Power
1.03
1.02
1.14
1.07
1.06
1.03
1.03
1.03
1.02
1.14
1.06
1.06
1.02
1.02
1.02
1.02
27