JVC AV-20420/SA Service Manual page 25

Advertisement

Measuring
Item
instrument
MTS
Signal
STEREO VCO
generator
Frequency
counter
Remote
control unit
Setting item
2. FH MON
3. ST VCO
MTS SAP
Signal
VCO
generator
Frequency
counter
Remote
control unit
Resistor
[1M ohm]
Setting item
8. 5FH MON
9. SAP VCO
MTS FILTER
Remote
check
control unit
Setting item
5. FILTER
Test point
Adjustment part
R OUT
[SOUND]
[AUDIO OUT]
<2. FH MON>
<3. ST VCO>
Initial setting value
0
38
MPX
[SOUND]
Connector
<8. 5FH MON>
4pin SDA
<9. SAP VCO>
3pin GND
R OUT
[AUDIO OUT]
Initial setting value
0
40
[SOUND]
<5. FILTER>
Initial setting value
35
Description
(1) Receive the RF signal (no modulated sound signal)
from the antenna terminal.
(2) Select the <2. FH MON> of SOUND mode, and
change the setting value from 0 to 1.
(3) Connect the frequency counter to R OUT of the
AUDIO OUT.
(4) Select the <3. ST VCO>.
(5) Set the initial setting value of the <3. ST VCO>.
(6) Adjust the <3. ST VCO> so that the frequency
counter will display 15.73kHz
(7) Select the <2. FH MON> of the SOUND mode, and
reset the setting value from 1 to 0.
(1) Receive the RF signal (non modulated sound signal)
from the antenna terminal.
(2) Connect the 1M ohm resistor between the pin [4] and
pin [3] of MPX connector.
(3) Select the <8. 5FH MON> of the SOUND mode, and
reset the setting value from 0 to 1.
(4) Connect the frequency counter to R out of the
AUDIO OUT.
(5) Select the <9. SAP VCO>.
(6) Set the initial setting value of <9 SAP VCO>.
(7) Adjust the <9. SAP VCO> so that the frequency
counter will display 78.67kHz
(8) Select the <8. 5FH MON> of the SOUND mode, and
reset the setting value from 1 to 0.
(1) Select the <5. FILTER> of the SOUND mode.
(2) Verify that the <5. FILTER> is set at its initial setting
value.
AV-20420
AV-20421
±
0.1kHz.
±
0.5kHz.
(No.52111)1-25