Removal And Replacement - Scotsman CS0415 Service Manual

Cuber
Hide thumbs Also See for CS0415:
Table of Contents

Advertisement

Removal and Replacement

Electrical Shock Hazard
Electrical shock can
cause personal injury.
Disconnect electrical
power before proceeding.
7. Disconnect the water fill tube from the pump
mounting bracket.
8. Disconnect the two wire pump connectors from
the harness block.
9. Remove the two thumbscrews from the reservoir
and remove the reservoir from the ice maker.
10. Remove the pump outlet tube.
11. Remove three hex-headed screws from the
pump mounting bracket and remove pump
assembly.
Water Fill
Tube
Pump Outlet
Tube
12. Separate the recirculation pump from the
bracket.
Reservoir Drain Pump and /or Water Level Sensor
1.
Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Unscrew the drain cap from the reservoir, drain
the water, and replace the cap tightly.
4. Remove the recirculating pump cover hexhead
screw.
5. To remove reservoir drain pump:
a) Disconnect the reservoir drain pump electrical
connection.
b) Remove the pump retaining screw and bracket.
c) Rotate the pump 1/4 turn and pull it down and
out of reservoir.
6. To remove the water level sensor:
a) Disconnect the water level sensor electrical
connection.
b) Remove the retaining clips, if present.
c) Pull the sensor up and out of the bracket.
July 2007
Page 22
CS0415
Service Manual
Water Level
Sensor

Advertisement

Table of Contents
loading

Table of Contents