Chimney Components - Heat & Glo EXCLAIM-36 Owner's Manual

Woodburning fireplace
Hide thumbs Also See for EXCLAIM-36:
Table of Contents

Advertisement

C. Chimney Components
The following pictures show only those chimney components which may be safely used with this fi replace.
Catalog #
US
CAN
Description
CAK5A
CAK5A
Chimney Air Kit
ID4
ID4
Insulated Duct/Outside Air
UD4
UD4
Uninsulated Duct/Outside Air
SL1106
SL406
Chimney Section - 6 in. (152 mm) long
SL1112
SL412
Chimney Section - 12 in. (305 mm) long
SL1118
SL418
Chimney Section - 18 in. (457 mm) long
SL1136
SL436
Chimney Section - 36 in. (914 mm) long
SL1148
SL448
Chimney Section - 48 in. (1219 mm) long
SL11
SL4
Chimney Stabilizer
SL1130
SL430
Chimney Offset/Return - 30 deg
FS538
FS538
Ceiling Firestop - Straight
FS540
FS540
Ceiling Firestop - 30 deg
AS10
AS10
Straight Attic Insulation Shield, 24 in. (610 mm)
JB577
JB577
Chimney Joint Band
CB576
CB576
Chimney Bracket
RF570
RF570
Roof Flashing - Flat to 6/12 Pitch
RF571
RF571
Roof Flashing - 6/12 to 12/12 Pitch
TR11
TR444
Round Termination Cap
TR11T
TR442
Round Telescoping Termination Cap
TCT1175
Terra Cotta Termination Cap
ST1175
ST475
Square Termination Cap
CT56
CT56
Chase Top
LDS33
LDS33
Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)
LDS46
LDS46
Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)
Decorative Shroud - 26 in. x 26 in.
LDS-BV
LDS-BV
(660 mm x 660 mm)
Field Constructed Shrouds (See "Woodburning
Termination Cap")
CT11-King
n/a
European Copper Termination Cap - King Style
CT11-Queen
n/a
European Copper Termination Cap - Queen Style
CT11-Bishop
n/a
European Copper Termination Cap - Bishop Style
CT11-Knight
n/a
European Copper Termination Cap - Knight Style
CT11-Pawn
n/a
European Copper Termination Cap - Pawn Style
14 in.
(356 mm)
`
5-1/4 in.
(133 mm)
13 in.
(330 mm)
CAK5A - Chimney Air Kit
(required in Canaga)
42
Heat & Glo • EXCLAIM-36 US-CAN Woodburning Fireplace • 4013-204 Rev D • 06/07
14 in.
(356 mm)
4 in. (102 mm)
SL11/SL4 - Chimney Stabilizer
(required in Canada)
ID4 Insulated Duct
42 in.
(1067 mm)
UD4 Uninsulated Duct
42 in.
(1067 mm)
A
11 in.
(279 mm)
B
Chimney Sections
Catalog #
US
CAN
in
SL1106
SL406
6
SL1112
SL412
12
SL1118
SL418
18
SL1136
SL436
36
SL1148
SL448
48
A = Actual Length
B = Effective Length (length of
chimney part after it has
been snapped to another)
0-3/4 in.
527 mm)
18 in.
(457 mm)
SL11/SL4 - Chimney Stabilizer
4 in. (102 mm) i
4 in. (102 mm) i
13 in.
(330 mm)
A
B
mm
in
mm
152
4-3/4
121
305
10-3/4
273
457
16-3/4
425
914
34-3/4
883
1219
46-3/4
1187
Inside Diameter
SL4 - 10 in. (254 mm)
SL11 - 11 in. (279 mm)
Outside Diameter
13 in. (330 mm)

Advertisement

Table of Contents
loading

Table of Contents