HOW TO SET UP YOUR
UNIT
Air Compressor Location
Locate the air compressor in a
clean, dry, and well ventilated
area.
Locate the air compressor at
least 12" away from the wall
or other obstructions that will
interfere with the flow of air.
Locate the air compressor as
close to the main power supply
as possible to avoid using long
lengths of electrical wiring.
NOTE: Long lengths of electrical
wiring could cause power loss to
the motor.
The air filter must be kept
clear of obstructions which
could reduce air flow to the air
compressor.
Anchoring of the Air
Compressor
Excessive vibration
air tank and cause an explosion.
The compressor must be properly
mounted.
The air compressor MUST be bolted
to a solid, level surface.
Hardware needed:
4 - Concrete anchors (not
supplied)
4 - 3/8" Lag screw to fit
concrete anchors (not
supplied)
4 - 5/8" Washer (found in parts
bag)
- shims (if needed)
1.
Place the air compressor on a
solid, level surface.
2.
Mark the surface using the holes
in the air compressor feet as a
template.

INSTALLATION

can weaken the
3.
Drill holes in the surface for
the concrete anchors. Install
concrete anchors.
4.
Line up holes in surface with
holes in air compressor feet.
5.
Place the (4) washers (supplied)
between the floor and air
compressor feet. If needed, solid
shims may be placed between
the washers and floor to evenly
distribute weight on all four feet.
See next figure.
5/8" Washer
(supplied)
Shim Under
Washer
(not supplied)
6.
Place the (4) 3/8" lag screws
through the air compressor feet,
washers, shims, and into the
anchors.
7.
Torque 3/8" lag screws to 7-10
ft.-lbs.

Wiring Instructions

electrical grounding can result in
electrical shock. The wiring should
be done by a qualified electrician.
A qualified electrician needs to know
the following before wiring:
1.
The amperage rating of
the electrical box should
be adequate. Refer to the
Specification Table, in this
manual, for this information.
11- ENG
3/8" Lag
Screw
(not
supplied)
Surface Line
Concrete Anchor
(not supplied)
Risk of Electrical
Shock. Improper
A13576