    Therefore, a serial cable should be connected between the serial port on a PC and the serial port on a display. Main Screen Click Start > Program > Samsung > MDC System to start the program. Select a set to see the volume of the selected set within the slider.
  • Page 50: Port Selection

    Main Icons Select Button Remocon Info Grid Safety Lock Display Selection Port Selection Control Tools 1. Use the main icons to switch into each screen. 2. Allows you to enable or disable the remote control signal receiving function of the display unit. 3.
  • Page 51: Power Control

    1. The Multiple Display Control is originally set to COM1. 2. If any port other than COM1 is used, COM1 through COM4 can be selected in the Port Selection Menu. 3. If the exact port name that is connected to the LCD Display using a serial cable is not selected, communication will be unavailable.
  • Page 52 Info Grid shows some basic information necessary to Power Control. (Power Status) 2) Input 3) Image Size 4) On Timer 5) Off Timer 2. Use the Select All button or Check Box to choose a display to control.
  • Page 53: Input Source

    Power Control allows controlling some of the functions of the selected display. 1) Power On/Off - Turns the power of the selected display On/Off. 2) Volume - Controls the volume level of the selected display. It receives the volume value of the selected display from the sets and displays it in the slider. (When you cancel the selection or choose Select All, the value returns to the default value 10) (Mute On/Off) - Turns on/off the Mute function of the selected display.
  • Page 54 • PC Mode...
  • Page 55 Info Grid shows some basic information necessary to Input Source Control. - Changes the Input Source of the selected display to PC. - Changes the Input Source of the selected display to BNC. - Changes the Input Source of the selected display to DVI. - Changes the Input Source of the selected display to TV.
  • Page 56: Image Size

    The Input Source Control feature is available only for the displays whose power status is ON. Image Size PC, BNC, DVI 1. Click Image Size of the main icons and the Image Size control screen appears. Info Grid shows some basic information necessary to Image Size Control. ( Power Status) - Shows the power status of the current display.
  • Page 57 Image Size TV, AV, S-Video, Component, DVI(HDCP), HDMI, DTV 1. Click Image Size of the main icons and the Image Size control screen appears. Info Grid shows some basic information necessary to Image Size Control. 1) Click the Video Source tab to adjust Image Size for TV, AV, S-Video, Component, DVI(HDCP), HDMI, DTV. Click Select All or use Check Box to select a display to control.
  • Page 58 1. Click Time of the main icons and the Time Control screen appears. Info Grid shows some basic information necessary to Time Control. 1) Current Time - Set the current time for the selected display (PC Time). - To change the current time, first change the PC Time. 2) On Time Setup - Set the Hour, Minute, AM/PM of On Time Setup, Status, Source, Volume of the selected display.
  • Page 59: Pip Size

    PIP Size 1. Click PIP of the main icons and the PIP control screen appears. Click Select All or use Check Box to select a display to control. Info Grid shows some basic information necessary to PIP Size Control. 1) PIP Size - Shows the current PIP Size of the display in use.
  • Page 60: Pip Source

    PIP Source 1. Click PIP of the main icons and the PIP control screen appears. Info Grid shows some basic information necessary to PIP Source Control. 1) PIP Source - PIP Source can be controlled with turning on the LCD Display power. 2) PC - Changes the source of the PIP of the selected display to PC.
  • Page 61 Settings Picture 1. Click Settings of the main icons and the Settings Control screen appears. Info Grid shows some basic information necessary to Settings Control. When each function is selected, the set value of the selected function is displayed in the slide.When selected, each function fetches the value for the set and displays it on the slide bar.
  • Page 62: Picture Pc

    - Adjusts the Color Tone for the selected display. 8) Color Temp - Adjusts the Color Temp for the selected display. 9) Brightness Sensor - Adjusts the Brightness Sensor for the selected display. 10) Dynamic Contrast - Adjusts the Dynamic Contrast for the selected display. The Input source of MagicInfo works only on MagicInfo model.
  • Page 63 2) Contrast - Adjusts Contrast of the selected display. 3) Brightness - Adjusts Brightness for the selected display. 4) Red - Adjusts red Color of the selected display. - Available only for NT. 5) Green - Adjusts green Color of the selected display. - Available only for NT.
  • Page 64 Info Grid shows some basic information necessary to Settings Control. When each function is selected, the set value of the selected function is displayed in the slide. When selected, each function fetches the value for the set and displays it on the slide bar. When "Select All" is chosen, the default value is displayed. Changing a value in this screen will automatically change the mode to "CUSTOM."...
  • Page 65: Image Lock

    Image Lock 1. Click Settings of the main icons and the Settings Control screen appears. Info Grid shows some basic information necessary to Settings Control. 1) Image Lock - Available only for PC, BNC. 2) Coarse - Adjusts Coarse of the selected display. 3) Fine - Adjusts Fine of the selected display.
  • Page 66 An "Info Grid" showing several basic data items appears. 1) Maintenance - Allows the Maintenance Control function for all input sources. 2) Auto Lamp Control - Automatically adjusts the backlight of the selected display at a specified time. The Manual Lamp Control automatically turns off if you adjust using the Auto Lamp Control. 3) Manual Lamp Control - Allows you to adjust the backlight of the selected display regardless of the time.
  • Page 67: Video Wall

    1) Scroll - This function is used to remove the afterimages that occur when a still screen is displayed on the selected display for a long time. 2) Pixel Shift - This allows the screen to be moved finely at the specified time interval. 3) Safety Screen - The Safety Screen function is used to prevent afterimages from occurring when a still screen is displayed on the monitor for a long time.
  • Page 68 Select a display from Display Selection. The place will be set up by pressing a number in the selected mode. The MDC program supplied by Samsung supports up to 5x5 LCD Displayes. 3) On / Off - Turns on/off the Video Wall function of the selected display.
  • Page 69: Troubleshooting

    You may not operate this function in MagicInfo. The Input source of TV works only on TV model. The Maintenance Control function is available only for the displays where the power status is ON. Troubleshooting 1. The display you wish to control does not appear on the Power Control Info Grid - Check the connection of RS232C.
  • Page 70 2. Selected one display: Fetches and displays the settings value for the selected display. 3. Selected one display (ID1) and add another display (ID3): The program, which was displaying the settings value of ID 1, fetches and displays the value of ID3. 4.