Before beginning installation, carefully read these instructions. This will simplify the installation and ensure
the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National
Fuel Gas Code ANSI Z223.1.
NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME USE
only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
www.frigidaire.com
Pre-Installation Requirements...................................2
Electrical Requirements...........................................2
Ventilation System Requirements............................. 3-4
Exhaust System Requirements..................................4
Gas Supply Requirements........................................4
Location of Your Dryer.............................................5
Mobile Home Installation.........................................6
Rough-In Dimensions...............................................6-7
Unpacking.............................................................7
Reversing Door Swing..............................................7-8
Electrical Installation................................................9
Grounding Requirements..........................................9
Electrical Connections-3-wire.................................10
Electrical Connections-4-wire.................................10
Gas Connection......................................................11
General Installation.................................................11
Replacement Parts..................................................11

Save These Instructions

1
P/N 134431700 (0405)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Frigidaire Gas & Electric Dryer

  • Page 1: Table Of Contents

    NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME USE only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc. Save These Instructions www.frigidaire.com P/N 134431700 (0405)
  • Page 2: Pre-Installation Requirements

    POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. For your safety the information in this manual must be followed to minimize the POWER SUPPLY CORD KIT - The dryer MUST employ a risk of fire or explosion or to prevent property 3-conductor power supply cord NEMA 10-30 type SRDT damage, personal injury or loss of life.
  • Page 3: Exhaust System Requirements

    EXHAUST SYSTEM REQUIREMENTS MAXIMUM LENGTH of 4” (10.2 cm) Dia. Rigid Metal Duct Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and approved vent hood which has a VENT HOOD TYPE swing-out damper(s) that open when the dryer is in (Preferred) operation.
  • Page 4: Gas Supply Requirements

    2. The gas supply line should be of 1/2 inch (1.27 cm) Although vertical orientation of the exhaust system is pipe. acceptable, certain extenuating circumstances could affect 3. If codes allow, flexible metal tubing may be used to the performance of the dryer: connect your dryer to the gas supply line.
  • Page 5 MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR FRONT Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 60 sq. inches Closet 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 1 (2.54 cm) (387.1 sq. cm) Closet door ventilation required: 2 louvered openings each 60 square inches (387 square centimeters) —...
  • Page 6: Dryer Installation Dimensions

    Dryer Installation Dimensions Free-Standing & Under Counter Electrical supply 48.5” To clear open door on rear of unit (123.19cm) Gas supply pipe 36" on rear of unit (91.44cm) (5.72cm) 2.25” (12.7cm) 5.0” Center line height for rear, right, left (34.29cm) 2.375”...
  • Page 7: Mobile Home Installation

    ACKING ACKING UNPACKING ACKING ACKING MOBILE HOME INSTALLATION 1. Using the four shipping carton corner posts (two on each side), 1. Dryer MUST be exhausted outside (outdoors, not beneath the carefully lay the dryer on its left side and remove the foam mobile home) using metal ducting that will not support shipping base.
  • Page 8 “Window Door” Reversal Instructions: 4. Remove 3. Remove 1. Open the dryer door. Remove the four hinge hole plugs Handle Screws Plastic Plugs from the left side of the door opening. Place nearby for future installation. NOTE: You may need a plastic knife to help pull out the plugs.
  • Page 9: Electrical Installation

    ELECTRICAL INSTALLATION 2. If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, ELECTRIC Dryer the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 10: Electrical Connections-3-Wire

    GREEN GREEN POWER CORD GREEN G R O U N D GROUND WIRE SILVER TERMINAL G R O U N D S C R E W SILVER TERMINAL S C R E W TERMINAL BLOCK NEUTRAL GROUND W I R E TIGHTEN BLACK N E U T R A L...
  • Page 11: Gas Connection

    1-800-944-9044, 4. Test all connections by brushing on a soapy water or visit our website, www.frigidaire.com, for the Frigidaire solution. NEVER test for gas leaks with an open Company Authorized Parts Distributor nearest you.
  • Page 12 NOTA: La secadora está clasificada para USO DOMESTICO solamente, de acuerdo con la norma ANSI Z 21.5.1 o ANSI/UL 2158 - CAN/CSA C22.2 (las últimas ediciónes). Esta secadora no se recomienda para uso commercial tal como en restaurantes, salones de belleza, etc. Conserve estas instrucciones www.frigidaire.com P/N 134431700 (0405)
  • Page 13: Requerimientos De Instalación Preliminares

    ALIMENTACIÓN ELÉCTRICA - Corriente alterna, monofásica, 60 Para su seguridad, siga las Hz, 240 voltios; trifilar o tetrafilar. instrucciones contenidas en este manual a fin CORDÓN ELÉCTRICO - En la secadora se DEBE usar un cordón de reducir a un mínimo los riesgos de incendio o eléctrico trifilar NEMA 10-30 tipo SRDT para un voltaje nominal mínimo de 240 voltios CA, 30 amp., con 3 conectores de explosión o para evitar daños materiales,...
  • Page 14 REQUERIMIENTOS DEL SISTEMA DE ESCAPE LARGO MÁXIMO del Conducto Metálico Rigido de 4” (10,2 cm) de Diámetro Utilice solamente ductos metálicos, rígidos o flexibles de 4" (10,2 cm) de diámetro (mínimo) y una caperuza de salida de uso TIPO DE CAPERUZA DE SALIDA aprobado, con registros que giren hacia afuera que se abren (Preferido) cuando la secadora se encuentra en funcionamiento.
  • Page 15: Requerimientos Del Suministro De Gas

    Aungue un sistema vertical sea aceptable, algunas circunstancias 2. La tubería de alimentación de gas debe ser de 1/2 pulgada atenuantes pueden afectar el funcionamiento de la secadora: (1,27 cm) de diámetro. • Se debe utilizar solamente conductos metalicos rigidos. Si está...
  • Page 16 DESPEJES MÍNIMOS DE INSTALACIÓN - Pulgadas (cm) Parte Parte Parte Lados Trasera Superior Delantera Alcoba 0 (0 cm) 0 (0 cm) 15 (38,1 cm) 60 Pulg.² 60 Pulg.² 60 Pulg.² 60 Pulg.² 60 Pulg.² (387,1 cm (387,1 cm (387,1 cm 2 2 2 2 2 ) ) ) ) ) Armario...
  • Page 17 Dimensiones De la Instalación Dryer Installation Dimensions Fuente eléctrica en la parte En el claro abra la puetra 48.5” To clear open door posterior de la unidad (123.19cm) Pipe de la fuente de gas en la parte 36" Gas supply pipe posterior de la unidad (91.44cm) on rear of unit...
  • Page 18: Dimensiones Para La Instalación

    INSTALACIÓN EN CASAS MÓVILES MODELOS AUTÓNOMOS CON CONSOLA 1. El tubo de escape de la secadora DEBE ser instalado hacia el SUPERIOR exterior (El escape debe colocarse en la parte exterior y no DIMENSIONES PARA LA INSTALACIÓN debajo de la casa móvil.) Debe usarse ducto de metal que no DESEMBALAJE sea combustible.
  • Page 19 Instrucciones De la Revocación De la Puerta De la Ventana 3. Quite Los 4. Quite Los Tapóns Plásticos Tornillos De la 1. Abra la puerta del secador. Quite los cuatro tapóns del agujero de la bisagra del lado izquierdo de la abertura de la Manija puerta.
  • Page 20: Instalación Eléctrica

    INSTALACIÓN ELÉCTRICA Secadoras ELÉCTRICAS La conexión indebida del conductor de puesta a Los siguientes requerimientos son tierra del equipo puede ocasionar un riesgo de choque eléctrico. específicos para el funcionamiento correcto y seguro de su Consulte con un electricista profesional si tiene alguna duda respecto secadora.
  • Page 21 TORNILLO TORNILLO VERDE CONDUCTOR VERDE DE VERDE DE DE PUESTA CORDÓN ELÉCTRICO BORNE PLATEADO PUESTA A A TIERRA TABLERO DE BORNES TIERRA BORNE PLATEADO CABLE DE PUESTA A TIERRA NEUTRAL CABLE DE PUESTA A TIERRA NEGRO NEUTRAL ATORNILLE LA TUERCA EN ESTAS BLANCO ROSCAS TUERCA...
  • Page 22: Conexión Del Gas

    1-800-944-9044, o visitan nuestros website ABIERTA PARA DETECTAR SI HAY FUGAS DE GAS. www.frigidaire.com, para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted. GENERAL INSTALACIÓN Cuando se reparan los controles, marque todos los cables con etiquetas antes de desconectarlos. Cualquier error de cableado puede causar una operación inadecuada y...