Sony CA-570 Operation Manual page 10

Camera adapter
Hide thumbs Also See for CA-570:
Table of Contents

Advertisement

4 Switch S1 on the DM-116 board
Selects the PROMPT/GENLOCK connector function.
PROMPTER: Inputs and outputs a prompter signal
(factory setting).
GENLOCK: Inputs an external sync signal.
Note
Swicth S1 on the DM-116 board is used for factory
inspection use only.
The PROMPTER/GENLOCK connector function is
normally specified using the PROMPTER/GENLOCK
switch on the MD-119 board.
5 Switch S4 on the DM-116 board
Selects the direction of the prompter signal flow
between the CCU and CAM.
CCU→CAM: The video signal from the CCU is
output from the PROMPTER/GEN LOCK
connector.
CAM→CCU: The signal input to the PROMPT/
GEN LOCK connector is output to the CCU.
Switch on the DM-116 board
A
LV3
RV3
FL4
LV4
RV4
CN5
B
TP4
E1
RV2
E2
TP5
CN4
FL5
C
S4
FL3
D
S1
CN3
FL2
FL1
E
LV2
RV1
LV1
F
CN2
TP3
G
4
3
2
1
6 S3 switch on the AU-237 board
Specifies whether the incom audio output from
INCOM 2 connector and the program audio are mixed
or not.
IND: No mixing (factory setting for NTSC)
MIX: Mix mode 2 (set by switch S5) (factory setting
for PAL)
7 Switch S4 on the AU-237 board
When this switch is set to ON, the program audio is
mixed with the intercom audio. The factory setting is
OFF.
8 Switch S2 on the AU-237 board
Specifies whether the incom audio output from
INCOM 2 connector and the program audio are mixed
or not.
IND: No mixing (factory setting for NTSC)
MIX: Mix mode 1 (set by switch S4) (factory setting
for PAL)
9 Switch S302 on the AU-237 board
Sets the INCOM 2 connector to either RTS mode or
NORMAL mode. The factory setting is NORMAL
mode.
0 Switch S411 on the AU-237 board
Sets the talk level through the TRACKER connector.
0 dB: Standard level
–20 dB: Decreases the talk level by 20 dB. (Select
this setting when the input level is too high.)
4 Switch S1
5 Switch S4
9(E)