General Data - LG LH247HV Engineering Manual

Single-zone ceiling-concealed duct (high static) heat pump systems 2 and 3 tons (24,000 btu/h) & (36,000 btu/h)
Hide thumbs Also See for LH247HV:
Table of Contents

Advertisement

Table 2: Ceiling-Concealed Duct (High Static) System General Data.
Type
System (Model) (Indoor Unit / Outdoor Unit)
Nominal Cooling Capacity (Btu/h)
Cooling Power Input
(kW)
1
Nominal Heating Capacity (Btu/h)
Heating Power Input
(kW)
1
Power Supply V, Ø, Hz
2
Outdoor Unit Operating Range
Cooling (°F DB)
Heating (°F WB)
Indoor Unit Operating Range
Cooling (°F WB)
Heating (°F DB)
Indoor Temperature Setting Range
Cooling (°F)
Heating (°F)
Unit Data
Refrigerant Type
3
Refrigerant Control
Indoor Unit Sound Pressure Level ±3 dB(A) (H/M/L)
Outdoor Unit Sound Pressure Level ±3 dB(A) (Cool/Heat)
Indoor Unit Net / Shipping Weight (lbs.)
Outdoor Unit Net / Shipping Weight (lbs.)
Power Wiring / Communications Cable (No. x AWG)
Power Supply (No. AWG)
Compressor (Type x Qty.)
Fan
Indoor Unit Type x Qty.
Outdoor Unit Type x Qty.
Motor / Drive
Airflow Rate
Indoor Unit (Max. / H / M / L [CFM])
Outdoor Unit (CFM)
Factory Set (High) External Static Pressure (in. wg)
Piping
Liquid (in.)
Vapor (in.)
Indoor Unit Condensate Drain O.D. / I.D. (in.)
Additional Refrigerant Charge (oz./ft.)
Maximum Pipe Length (ft.)
Piping Length (no additional refrigerant, ft.)
Maximum Elevation Difference (ft.)
EEV: Electronic Expansion Valve
IDU: Indoor Unit
ODU: outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level differ-
ence between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet bulb
(WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
general data / SPeCiFiCationS
LH247HV (LHN247HV / LUU247HV)
4
4
2
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Single Zone Ceiling-Concealed Duct (High Static)
24,000
2.0
27,000
2.28
208-230 / 1 / 60
5-118
0-64
57-77
59-81
65-86
61-86
R410A
EEV
38 / 36 / 35
48 / 52
73 / 95
133 / 146
4 x 18
3 x 12
Twin Rotary x 1
Sirocco x 1
Propeller x 1
Brushless Digitally Controlled / Direct
688 / 618 / 530
2,048
0.39
3/8
5/8
1-1/4 / 1
0.43
164
25
98
Power Input is rated at high speed.
1
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
2
comply with applicable and national code.
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
3
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
4
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.
LH367HV (LHN367HV / LUU367HV)
36,000
2.91
40,000
3.36
39 / 38 / 37
52 / 54
125 / 139
203 / 227
Propeller x 2
1,130 / 953 / 706
1,942 x 2
246
duct (HIgH StatIc) | 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lhn247hvLuu367hvLuu247hvLhn367hvLh367hv

Table of Contents