Heating Capacity Tables; Performance Data - LG LH247HV Engineering Manual

Single-zone ceiling-concealed duct (high static) heat pump systems 2 and 3 tons (24,000 btu/h) & (36,000 btu/h)
Hide thumbs Also See for LH247HV:
Table of Contents

Advertisement

Table 19: LH247HV Ceiling-Concealed Duct (High Static) System Heating Capacity Table.
Outdoor Air Temp.
Model No. /
Nominal Capacity
°F DB
°F WB
(Btu/h)
0
5
10
17
20
25
30
LH247HV
35
24,000
40
45
47
50
55
60
63
68
TC = Total Capacity (kBtu/h).
PI = Power input (KW). Power input (KW) includes compressor and fan(s).
Nominal capacity as rated 0 ft. above sea level and a 0 ft. level difference between outdoor and indoor
unit. Corresponding refrigerant piping length is accordance with standard length of each outdoor unit.
Table 20: LH367HV Ceiling-Concealed Duct (High Static) System Heating Capacity Table.
Outdoor Air Temp.
Model No. /
Nominal Capacity
°F DB
°F WB
(Btu/h)
0
5
10
17
20
25
30
LH367HV
35
36,000
40
45
47
50
55
60
63
68
TC = Total Capacity (kBtu/h).
PI = Power input (KW). Power input (KW) includes compressor and fan(s).
Nominal capacity as rated 0 ft. above sea level and a 0 ft. level difference between outdoor and indoor
unit. Corresponding refrigerant piping length is accordance with standard length of each outdoor unit.
32 | duct (HIgH StatIc)
61
TC
PI
TC
-0.4
13.59
1.70
12.80
4.5
15.90
1.73
15.16
9
17.45
1.75
16.74
15
19.15
1.78
18.48
19
20.18
1.81
19.54
23
21.90
1.85
21.25
28
23.63
1.90
22.89
32
25.35
1.95
24.54
36
26.64
2.00
25.89
41
28.26
2.07
27.58
43
28.90
2.10
28.26
46
28.99
2.09
28.40
51
29.13
2.07
28.65
56
29.27
2.04
28.89
59
29.35
2.03
29.03
64
29.44
2.02
29.18
61
TC
PI
TC
-0.4
10.89
2.36
10.10
4.5
16.13
2.42
15.33
9
19.64
2.47
18.83
15
23.50
2.54
22.68
19
25.84
2.59
25.02
23
29.74
2.67
28.86
28
33.65
2.77
32.61
32
37.55
2.87
36.36
36
39.47
2.95
38.36
41
41.86
3.06
40.86
43
42.82
3.10
41.86
46
42.94
3.08
42.08
51
43.15
3.05
42.44
56
43.36
3.01
42.80
59
43.49
2.99
43.01
64
43.61
2.97
43.23
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

PerFormanCe data

Indoor Air Temp. °F DB
64
68
PI
TC
PI
1.77
12.79
1.79
1.79
14.93
1.83
1.81
16.37
1.86
1.84
17.95
1.90
1.86
18.91
1.93
1.90
20.51
1.97
1.96
22.11
2.02
2.02
23.71
2.07
2.07
25.07
2.13
2.14
26.77
2.21
2.17
27.45
2.24
2.15
27.70
2.21
2.12
28.12
2.17
2.08
28.53
2.12
2.06
28.78
2.10
2.04
29.04
2.07
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
60ºF wet bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
Indoor Air Temp. °F DB
64
68
PI
TC
PI
2.45
10.27
2.49
2.51
15.16
2.56
2.56
18.43
2.62
2.62
22.03
2.70
2.67
24.21
2.76
2.75
27.86
2.86
2.86
31.49
2.95
2.97
35.12
3.05
3.05
37.14
3.14
3.16
39.66
3.26
3.20
40.66
3.30
3.17
41.04
3.26
3.12
41.65
3.20
3.07
42.27
3.13
3.04
42.64
3.09
3.01
43.02
3.05
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
60ºF wet bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

Heating capacity tables

70
72
TC
PI
TC
PI
12.50
1.81
12.26
1.82
14.62
1.85
14.36
1.87
16.04
1.88
15.77
1.90
17.60
1.93
17.32
1.96
18.55
1.96
18.26
1.99
20.12
2.01
19.81
2.04
21.70
2.06
21.38
2.10
23.28
2.12
22.94
2.15
24.63
2.18
24.29
2.21
26.32
2.25
25.97
2.28
27.00
2.28
26.64
2.31
27.30
2.25
26.98
2.27
27.79
2.19
27.54
2.21
28.29
2.14
28.09
2.15
28.59
2.11
28.43
2.11
28.89
2.07
28.77
2.08
70
72
TC
PI
TC
PI
10.02
2.51
9.82
2.53
14.83
2.59
14.57
2.61
18.06
2.66
17.75
2.69
21.60
2.75
21.25
2.79
23.75
2.81
23.38
2.85
27.33
2.91
26.91
2.96
30.91
3.02
30.45
3.07
34.49
3.12
33.98
3.18
36.49
3.21
35.98
3.26
39.00
3.32
38.47
3.36
40.00
3.36
39.47
3.41
40.44
3.31
39.97
3.35
41.18
3.23
40.79
3.26
41.91
3.15
41.62
3.17
42.35
3.10
42.12
3.12
42.80
3.06
42.62
3.06
75
TC
PI
11.75
1.89
13.79
1.93
15.15
1.96
16.65
2.01
17.56
2.04
19.07
2.10
20.59
2.15
22.11
2.21
23.41
2.27
25.02
2.35
25.67
2.38
26.07
2.34
26.72
2.26
27.38
2.18
27.77
2.14
28.17
2.10
75
TC
PI
9.38
2.62
13.98
2.70
17.05
2.77
20.44
2.87
22.49
2.93
25.89
3.04
29.33
3.14
32.76
3.25
34.68
3.34
37.07
3.46
38.03
3.51
38.62
3.44
39.59
3.33
40.56
3.22
41.14
3.15
41.73
3.09

Hide quick links: