Water Line Connections - GE AvantaPure Operation Manual

Avantapure professional series water treatment system
Table of Contents

Advertisement

Inspection
The AvantaPure system is shipped with several parts
unassembled. When parts are removed from the packing,
they should be inspected for damage. If any parts are
damaged or missing, contact your supplier.
WARNING: When handling the media
tank do not turn it upside down or drop on
its side.
When the carton is first opened, the softener will be
standing upright.
CAUTION!
REMOVE BRINE TANK SLOWLY
1
2
Figure 7
WARNING: The brine tank fits tightly over
the valve. When removing the brine tank tip
it forward and rotate slightly to pull off. Take
care not to damage valve cover or control.
To assemble the system, remove the salt tank components
(cover, tank and brine tube assembly) from the shipping
container.
1. Remove the brine well and parts bags.
2. Lift the brine tank up 2 feet.
3. Turn the brine tank 1/4 turn to the right.
4. Tilt the brine tank toward the label and slowly lift free.
The media tank can now be removed.
To assemble the Salt Tank:
1. Stand the salt tank up and in position. Level as needed.
The tank has two ports that will be connected. One to a
drain and one to the valve.
2. Remove the overflow fitting from the brine tube. Place
the brine tube in position. Align the large hole in the
brine well with the hole in the brine tank. Install the
overflow fitting in this hole to secure well to tank. Lay
cover aside for now.
To Assemble the Media Tank:
1. Stand the tank up and in position.
2. If the floor under the media tank is uneven, level as

Water Line Connections

A bypass valve system should be installed on all water
conditioning systems. A model 1265 bypass is included
with this system. Bypass valves isolate the conditioner
from the water system and allow unconditioned water to
be used. Service or routine maintenance procedures may
also require that the system is bypassed. service during
3
4
routine maintenance and servicing procedures. The
5
illustrations below show the two common bypass
methods.
12
needed.
WARNING: The media tank contains
loose particles that will shift. If the tank is
turned upside down or laid back quickly, the
particles may enter the valve. If this
happens, the valve may need to be
disassembled and cleaned.
Normal Operation
In
Out
Water Conditioner
Figure 8 Model 1265 Bypass (Included)
Normal Operation
Water Conditioner
Figure 9 Typical Three Valve Bypass Configuration
(Not provided by manufacturer)
In Bypa
Out
In
Water Conditioner
In Bypa
Water Conditioner