Toshiba TOSVERT VF-AS1 Brochure & Specs page 3

Transistor inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

For your commercial facilities, offices and factories
This makes the inverter ideal for your electronic applications such as
washing machines treadmill, showcase refrigerators for stores, medical
equipment, and stage equipment where attention must be paid to
peripheral devices.
*1:Photos of machinery are for illustrative purposes only.
Harmonics Reduction, Power Factor Improvement
Point
1
Effect of built-in reactor
Input current
Input current/voltage waveform
Input current/voltage waveform
300
600
300
600
200
400
200
400
100
200
100
200
0
0
0
0
0
200
400
600
0
200
400
600
-100
-200
-100
-200
-200
-400
-200
-400
-300
-600
-300
-600
Conventional models (400 V, 30 kW)
VF-AS1 (400 V, 30 kW)
Input current value 87.6 A
Input current value 58.8 A
Overall input power factor 59%
Overall input power factor 88%
High-frequency Noise Reduction
Point
POINT
2
Effect of built-in filter
Example of generated noise data
100
[dBuV]
EN61800-3 1st Environment Category C2
80
60
40
20
0.15
1
10
30
Frequency [MHz]
Built-in EMC filter
200V class models, 0.4 to 7.5kW : EMI noise filter (complies with the European EMC Directive) built-in standard
200V class models, 11 to 45kW : Basic noise filter (not complies with the European EMC Directive) built-in standard
400V class models, 0.75 to 75kW : EMI noise filter (complies with the European EMC Directive) built-in standard
400V class models, 90 to 500kW : EMI noise filter (complies with the European EMC Directive) built-in standard
3
• A compact, space-saving new type of DC reactor is built
into 200 V class 11 to 45 kW and 400 V 18.5 to 75 kW
models.
In addition to reducing harmonics, this reactor limits the
input current to 110% of the rated output current, and it has
been designed to be compatible with power supply systems
containing transformers, molded-case circuit breakers, and
power lines.
Adding on the optional DC reactor enables compliance with
IEC harmonics standards.
• High-frequency noise is drastically reduced on models with
built-in noise filters. Built-in noise filters are ideal for sites
from commercial facilities and offices through to factories
where attention must be paid to peripheral devices.
Compared with filter not integrated models, space and
wiring savings have been achieved by incorporating the
filter in the panel. Also, models with built-in EMC noise
filter comply with the European EMC Directive as
individual inverter units.
European EMC Directive : IEC/EN61800-3, 1st Environment, C2
200V-0.4 to 1.5kW
400V-0.75 to 3.7kW
or
IEC/EN61800-3, 2nd Environment, C3
For machinery that requires simple function
This makes the inverter ideal for drilling machines, handling machines,
conveyors, semiconductor production equipment, cutting machines, and
woodworking machinery that require simple function.
*1:Photos of machinery are for illustrative purposes only.
Simple Setup by EASY Key
Point
3
• In the Quick mode, pressing the EASY key on the panel allows
EASY key
you to operate the inverter by eight basic parameters.
When setting each of the functions, press the EASY key to move
to the standard mode by one-touch operation. In this mode, you
can access all parameters.
• You can customize the Quick mode display, maximum of 32
Quick mode (EASY)
target parameters are displayed to suit your specific setup
Title
Function
Parameter setting macro function
requirements.
V/f control mode selection
Maximum frequency
• You can also use the EASY key as a panel/remote key to switch
Acceleration time 1
Deceleration time 1
between panel and remote operation, and as a shortcut key to
Motor overload protection level 1
FM terminal meter adjustment
directly access any specific setup or display screen.
Parameter display selection
Easy Installation, Easy commissioning, and Easy maintenance
Point
4
Side-by-side installation
Side-by-side installation
• Side-by-side installation of inverters is possible up to the inverter's
total capacity. This allows effective utilization of space inside
control panels. Heat sink can be installed outside of the panel as
an option.
Removable control terminal board
• A removable terminal board is used. This allows you to use the
Removable control terminal board
control wiring when replacing the inverter, which also makes
maintenance easier.
ON/OFF control of cooling fan
• Temperature-based ON/OFF control reduces noise while the inverter
is being stopped, saves energy and extends the cooling fan's life.
Monitoring of serviceable parts/alarm output
• The expected replacement cycle of main circuit capacitors,
capacitors on control board, and cooling fan is monitored, and an
alarm is output when the cycle is reached.
4

Advertisement

Table of Contents
loading

Table of Contents