Overview and Site Preparation
OVERVIEW
Read through the entire manual before beginning your
installation.
There are seven steps to installing your Drinking Water
system. They are as follows:
STEP A - Install Cold Water Supply Fitting
STEP B - Install Drain Adapter
STEP C - Install Reverse Osmosis Assembly
STEP D - Install Storage Tank
STEP E - Install Reverse Osmosis Faucet
STEP F - Connect Tubing
STEP G - Sanitize, Pressure Test & Purge System
These steps are explained in detail over the next few
pages. Follow all steps. Reading this manual will also
help you receive and use all the benefits your Reverse
Osmosis system can give you.
Questions? Call Toll Free 1-866-986-3223
When you call, please be prepared to provide the model, date code and serial number,
or visit www.whirlpoolwatertreatment.com
found on the rating decal, located inside the cover.
PREPARE SITE FOR INSTALLATION
1. Before starting, close the hot and cold water shutoff
valves (See Figure 6).
2. Temporarily place tank and filter assembly into
planned location. Check position of items and space
required for proper installation. Ensure tubes may
be routed without kinking.
3. Remove tank and filter from planned location and
set aside.
NOTE: You must check and comply with all local
plumbing codes.
NOTE: Codes in the state of Massachusetts require
installation by a licensed plumber and do not per-
mit the use of saddle valves.
If you live in the state of Massachusetts, review
plumbing code 248-CMR of the Commonwealth of
Massachusetts before proceeding with the installa-
tion.
NOTE: For best system performance, the feed
water to the system should be softened or have
hardness less than 10 grains per gallon, with no
iron.