— Installation and service must be performed by a qualified installer, service agency or the gas supplier. Manufactured by: Distributed By: Biasi S.p.A. Quincy Hydronic Technology, Inc. Verona, Italy 3560 Lafayette Road Portsmouth, NH 03801 Phone: 603-334-6400 Fax: 603-334-6401 RIVA COMBI MANUAL - REV B...
Page 3
CSA 4.9 and is CSA compliant. This Riva Combi has a 2 year warranty, a copy of which is provided with the boiler. Please be sure to return the warranty registration card as the warranty will be void without your boiler's serial numbers (located on the ratings label affixed to the boiler), date of installation and the name of your installer being on record in our files.
Checking the Pressuriz. in C.h. Vess. 17.6 Checking the Pressuriz. in D.h.w. Vess. 17.7 Checking the Magnesium Anode 17.8 Cleanig the Burner 17.9 Checking the Flue 17.10 Visual Inspection of Appliance 17.11 Gas Pressures and Soundness 17.12 RIVA COMBI MANUAL - REV B...
Page 6
— Installation and service must be performed by a qualified installer, service agency or the gas supplier. DANGER Caution: Do not store or use flammable materials, chemicals or flammable liquids, especially gasoline, in the vicinity of this heating appliance. RIVA COMBI MANUAL - REV B...
Page 7
VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR BIASI RIVA COMBI BOILER. RIVA COMBI MANUAL - REV B...
- B149 Installation Codes E. ANSI/ASME - CSD-1 The above codes are available from: National Fire Protection Association (NFPA) CSA International Battery March Park 8501 E. Pleasant Valley Road Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575 http://www.nfpa.org http://www.csa-international.org RIVA COMBI MANUAL - REV B...
1. General Information The Riva Combi is a high efficiency, non-condensing, wall mounted gas boiler which provides central heat and domestic hot water. The boiler features a gas valve which modulates the energy input from 44,000 BTU/h to 108,000 BTU/h. The boiler is shipped fully assembled with the components listed on page 11.
Page 10
3.25/5 Sides Twin split pipes 3.25/3.25 Bottom Nominal heat flow rate 122.8 Flue pipe enclosed (0/2000ft) Flue pipe free air Nominal heat flow rate 116.7 (2000/4500ft) Min Exhaust temperature °F Max Exhaust temperature °F RIVA COMBI MANUAL - REV B...
37 Pressure reducing automatic fill valve 18 Modulation operator 38 Backflow preventer 19 Gas valve outlet pres. Test point 39 Gas supply line cock 20 Gas valve inlet pres. Test point 40 D.h.w. inlet cock RIVA COMBI MANUAL - REV B...
Pressure Relief Valves (#24, #25) should be piped to a drain or to the floor as close as possible to a drain. • This diagram is a graphical representation only and is not drawn to scale. Do not use for piping purposes. RIVA COMBI MANUAL - REV B...
Caution: Label all wires prior to disconnection when ye - yellow servicing controls. Wiring errors can cause vt - violet og - orange improper and dangerous operation. gnye - green/yellow Verify proper operation after servicing RIVA COMBI MANUAL - REV B...
Air Opening 0 to 12" Figure 6.2 When choosing an installation location insure the exhaust and intake pipes comply with NFPA 54. The drawing on the next page illustrates the restrictions on exhaust locations. RIVA COMBI MANUAL - REV B...
USE ONLY LISTED COMPONENTS SUPPLIED WITH THE BOILER. SURFACE DISCOLORATION OF THE BUILDING MAY OCCUR DUE TO IMPROPER INSTALLATION. QHT WILL NOT ACCEPT RESPONSIBILITY OR LIABILITY FOR SUCH DISCOLORATION. The Exhaust Hood must be installed on the leeward side of house and conform to the following guidelines: 1.
If you are using a separate pipe system drill holes marked B and C (ø 3.25”) shown below as well as on the paper template. Remove paper template and hang boiler on bracket. RIVA COMBI MANUAL - REV B...
If additional flue piping is need for a particular application, it can be ordered separately in 3 feet increments. Depending on the final flue pipe length, an alternative restrictor may be required. Refer to the tables 9.1 for proper restrictor ring sizing RIVA COMBI MANUAL - REV B...
9. Venting Cont. 9.3 Choice of flue: The following flue kits are available for connecting to the boiler: Standard coaxial horizontal flue kit (Exhaust & intake outside) RIVA COMBI MANUAL - REV B...
Page 21
• Secure elbow to boiler using gasket and four screws provided. • Secure end cap on the intake pipe outside the house. 9. Venting Cont. Standard separate horizontal flue kit (Exhaust & intake outside) RIVA COMBI MANUAL - REV B...
Page 22
• Connect each pipe to its corresponding elbow (as shown in the diagram). • Secure end cap on the intake and exhaust pipe outside the house. 9. Venting Cont. Alternative separate configuration (Exhaust outside & intake inside) RIVA COMBI MANUAL - REV B...
Page 23
• Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow. 9. Venting Cont. Alternative separate kit (Exhaust outside & intake inside) RIVA COMBI MANUAL - REV B...
Page 24
Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow. 9. Venting Cont. Alternative separate kit (Exhaust & intake outside) RIVA COMBI MANUAL - REV B...
Page 25
Connect each pipe to its corresponding elbow (as shown in the diagram). • Secure end cap on the intake and exhaust pipe outside the house. 9. Venting Cont. Standard Vertical-roof kit (Exhaust & intake outside) RIVA COMBI MANUAL - REV B...
The Riva boiler is supplied with a 3/4” stainless steel gas pipe (A in figure 10.1), 4 - 3/4” copper pipe (C,D,J,K in figure 10.1), 2 - 1/2” copper pipe (E,H in figure 10.1), located in a RIVA COMBI MANUAL - REV B...
Page 27
• Attach the supplied the suggested piping components to the diagrams in Section 4 boiler connections (page 12). (see Figures 10.1). Be sure to RIVA COMBI MANUAL - REV B...
The boiler and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). WARNINGS DO NOT USE A FLAME FOR CHECKING GAS LEAKS RIVA COMBI MANUAL - REV B...
Note: Do not connect live wires to thermostat terminals 1-3. Power supply terminal block External controls terminal block Figure 12.5 • Connect the earth wire(yellow/green). Boiler must be wired directly to earth ground on breaker panel. RIVA COMBI MANUAL - REV B...
To the external control device To the fused spur isolation switch as illustrated in Fig. • Replace the control 12.12. panel reversing the steps on page 23. Figure 12.12 RIVA COMBI MANUAL - REV B...
The d.h.w. expansion vessel (25 on page 11) allows the expansion of the water inside the storage tank (16 on page 11) and also absorbs the water hammer inside the pipe. RIVA COMBI MANUAL - REV B...
14.2. It is important that the separator be at least 2” in size to ensure proper performance. Boiler supply Boiler Return No more than 8" ¾” 1 ¼” 2" System supply System return At least 16" RIVA COMBI MANUAL - REV B...
Page 35
All external piping components are to be supplied by the installer. It is very important to use an hydraulic separator before secondary circulators. BIASI RIVA COMBI BOILER SECONDARY CIRCULATOR BOILER SUPPLY BOILER RETURN ELIMINATION HYDRAULIC BACKFLOW SEPARATOR PREVENTOR AND PRESSURE REDUCING VALVE RIVA COMBI MANUAL - REV B...
Page 36
All external piping components are to be supplied by the installer. It is very important to use an hydraulic separator before secondary circulators. Biasi Riva Combi Boiler Zone Valves Secondary Boiler Return Boiler Supply Circulators Air Elimination Backflow Preventor Hydraulic Separator Pressure Reducing Valve RIVA COMBI MANUAL - REV B...
14.3 Manifold Piping with Zone Valves or Circulators (shown conn. to radiators): All external piping components are to be supplied by the installer. Biasi Riva Combi Boiler Biasi Steel Boiler Return Boiler Supply Panel Radiators Backflow Preventor Pressure Reducing Valve Zone Valves RIVA COMBI MANUAL - REV B...
2 (Fig. 15.3); release the pump by turning the Figure 15.2 rotor in the direction • Open the installer indicated by the arrow supplied automatic fill RIVA COMBI MANUAL - REV B...
• Disconnect the gas taps and disconnect maximum position. If modulator coil by the pressure gauge. external controls are Important: after the checks all of the test points must be sealed. RIVA COMBI MANUAL - REV B...
(D on Figure 15.4). To reset the boiler turn the knob B (figure 15.4) on the 0 position and then press and release the boiler reset button (C on Figure 15.4). RIVA COMBI MANUAL – REV B...
15.8 and • By rotating the device point 19 (figure 15.6). ensure that the room clockwise the • Reassemble the front pressure increases. pannel of the case. RIVA COMBI MANUAL – REV B...
All the labels supplied with the boiler are numbered for reference. According to Figure 15.11 place all the labels on the boiler. Use label numbered as 1 (already installed in the front panel) to begin the placement in the correct way. RIVA COMBI MANUAL – REV B...
Gas supply the switch 2 • Loosen the screws C Natural gas and remove the front L.P.G. panel of the Figure 16.3 combustion chamber • Carry out the moving it to the left for RIVA COMBI MANUAL – REV B...
Page 45
• Turn on the boiler. indicating the type of • Calibrate the gas gas, and the gas valve according to the pressures to which instructions given in the appliance has section 15.5 of this been set. manual. RIVA COMBI MANUAL – REV B...
(37 on Section • Open the central heating drain cock (F in Fig. 17.4). • Loosen the d.h.w. Figure 17.4 storage tank air purge Figure 17.5 valve (G in Fig. 17.5) RIVA COMBI MANUAL – REV B...
• • Remove the vent connector from Using a flashlight inspect each the boiler by pulling vertically on length of vent pipe for obstructions and dirt build up. RIVA COMBI MANUAL - REV B...
17.13 Gas pressures and soundness: Check appliance for gas soundness. Recheck operational pressures and adjust as necessary as described in Section 15.5 page 32 of this manual. RIVA COMBI MANUAL - REV B...
Page 49
Separate vent sealing gaskets Separate vent 90 degree elbows Boiler vent adapter hardware Separate flue intake pipe Separate flue intake boiler adapter Separate flue exhaust boiler adapter Exhaust adapter gasket Exhaust restrictor Separate flue intake termination RIVA COMBI MANUAL - REV B...
Page 50
Order Number Coaxial intake pipe Coaxial termination pipe Coaxial union clamp Coaxial union gasket Coaxial exhaust gasket Coaxial boiler adapter gasket Coaxial boiler adapter Coaxial boiler adapter hardware Coaxial union clamp hardware Wall gaskets RIVA COMBI MANUAL - REV B...