TYPICAL VENT INSTALLATIONS

FIGURE 3

SPECIAL VENT INSTALLATION

PERISCOPE TERMINATION
Use the
GD201
periscope kit to locate the air termination
above the grade. The periscope must be installed so that
when final grading is completed, the bottom air slot is
located a minimum of 12 inches above the grade. The
maximum allowable vent length depends on the model
of fireplace, as illustrated.
FIGURE 5
FIGURE 4
For optimum performance, it is
recommended that all horizontal runs
have a 1 inch rise per foot.
When terminating vertically, the vertical
rise is a minimum 36 inches and a
maximum 40 feet from the center of the
fireplace flue outlet.
7
W415-0434 / D / 09.06.07