Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL,
CUL, ETL, CETL, have been evaluated by OSHA certified independent safety
laboratories and meet the applicable Underwriters Laboratories Standards for
Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you
continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically. The low pressure at which the motor
automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run,
air pressure in the air tank begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity. The high pressure at which the motor shuts
off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
This air compressor pump is capable of running continuously. However, to
prolong the life of your air compressor, it is recommended that a 50%-75%
average duty cycle be maintained; that is, the air compressor pump should not
run more than 30-45 minutes in any given hour.
Model No.
Running Horsepower
Bore
Stroke
*
Voltage-Single Phase
* * Minimum Branch Circuit Requirement
*
Fuse Type
Air Tank Capacity (Gallon)
Approximate Cut-in Pressure
Approximate Cut-out Pressure
SCFM @ 40 PSIG
SCFM @ 90 PSIG
Accessories for this unit are available at the store the unit was purchased.
One accessory available for this
unit is the Job Boss ™ Mobility Kit,
this accessory includes retractable
handle, comfort grip, mounting
bracket, pneumatic wheels, shoulder
bolts, and all associated hardware
needed to make this unit more
mobile.
A08193
GLOSSARY

DUTY CYCLE

SPECIFICATIONS

ACCESSORIES
8- ENG
C3550
1.3
2.363
0.890
120
15 amps
Time Delay
4.5 ASME
120 PSIG
150 PSIG
5.7
4.4