1. Make sure the filter pump switch is "OFF". The switch is located on the motor
housing.
2. Connect the power cord to a GFCI protected electrical outlet.
Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI). Contact a
qualified electrician if you cannot verify that the receptacle is protected by
a GFCI.
To prevent air lock, open the lower plunger valve (connected inlet hose)
first and then the upper plunger valve (connected outlet hose). Open air
release valves, wait until water starts to flow out of the air release valves,
close air release valves.
3. Grasp a plunger valve handle. Turn the handle counter-clockwise, pull up until
it stops, and then turn it clockwise until the metal protruding notch anchors in
the "0/1" position. Repeat for the 2nd plunger valve. This opens the valves to
allow water to flow into the filter pump.
4. With water flowing into filter pump, the water pressure will allow the air trapped
inside to escape from the air release valves (2 & 7). When all the air has
escaped water will flow out of the valves (2 & 7). When this occurs gently finger
tighten the valves (2 & 7) in a clockwise direction.
5. Turn the switch "ON". The filter pump is now filtering the water.
6. Operate the filter pump until the desired water clarity is obtained.
FILTER CARTRIDGE CLEANING OR REPLACEMENT
It is recommended that the filter cartridge be replaced at least
every 2 weeks.
1. Make sure the filter pump is turned off, and disconnect the power cord from the
electrical outlet.
2. Close both plunger valves. Grasp a plunger valve handle. Turn the handle
counter-clockwise, push down until it stops and then turn it clockwise until the
plastic protruding notch anchors in the "0/1" position. Repeat for the 2nd
plunger valve. This prevents the water from flowing out of the pool.
3. Gently turn the top air release valve 1-2 turns in a counter-clockwise direction.
This will allow the housing cover to be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a
safe location.
5. Remove the housing cover (4).
6. Remove the "OLD" filter cartridge.
7. Examine the inside of the filter housing.
SAVE THESE INSTRUCTIONS
(109) MODEL 633 FILTER PUMP ENGLISH 7.5" X 10.3" PANTONE 295U 09/26/2008

OPERATING INSTRUCTIONS

WARNING
IMPORTANT
English
109
Page 10