4.13 Information on failure display
and trouble-shooting
If a malfunction occurs, the indicator LED
"Failure" (1) flashes and LED (2) simultane
1
ously. In the case of AES models an acoustic
alarm sounds for 30 s. If the failure is not
resolved, it repeats after 1 h.
4.13.1 Status messages on the display
1
Mode
1
2
(1) + (2) = Indicator LED failure
(3) = Operating mode display
3
(4) = Temperature level display
4
Display :
MES
LED is flashing
LED is flashing
LED is flashing
All temperature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
2
3
AES
"230" is flashing
"12" is flashing
"GAS" is flashing
All temperature setting
LEDs are flashing
"HE1" is flashing
"HE2" is flashing
23
Refrigerator operation
4
Failure :
230V mode: "230V" not available or voltage too
low
12V mode: "12V" not available or voltage too low
GAS/Auto mode: Flame not ignited
Temperature sensor defective, refrigerator works
on mid temperature setting
230V - Heating element defective
12V - Heating element defective
2
Fig. 35