Installer Setup Menus and Options (continued)
Menu
5.2.6 ADVANCED
SENSORS
5.2.7 ADVANCED
ZONING
Please refer to the Zone Panel Installer's Guide for detailed information.
18-HD64D1-4
Setting
Select Outdoor Temperature Sensor................................................ None
Calibrate Outdoor Temperature Sensor - Degrees .......................... +/- in 5° Increments
Calibrate Indoor Temperature Sensor - Degrees ............................. Zone X in +/- 5° Increments
Calibrate RH Sensor ........................................................................ Zone X in +/- 5° Increments
Thermostat Humidity Sensor ........................................................... Disable
Damper Travel Time ......................................................................... 15 - 60 Seconds
Auto Detect Damper ........................................................................ No, Yes
Detected Dampers ........................................................................... 2 - 8
Run Auto Zone Airflow Capacity ...................................................... No, Yes
Auto Zone Airflow Capacity Adjustment ........................................... Normal
Airflow Capacity - % of Total ............................................................ 25% - 100%
Voting Zones .................................................................................... No, Yes
Indoor Heating Airflow Offset % (above and below cooling airflow) . -50 - +50, 0
Discharge Temperature Limit - Cooling ............................................ Normal (38), Extended (34)
Discharge Temperature Limit - Compressor Heating Only ............... Normal (116), Extended (128)
Discharge Temperature Limit - Compressor Heating w/Aux Heat .... Normal (160), Extended (170)
Heating Fuel Type ............................................................................ Gas
Discharge Temperature Limit - Gas Furnace Heating ...................... Normal (135), Extended (145)
Discharge Temperature Limit - Oil Furnace Heating ........................ Normal (160), Extended (170)
Discharge Temperature Limit - Hydronic Heating ............................ Normal (135), Extended (145)
Available Options
Sensor Wired to Control
CLII/AccuLink Outdoor Sensor
Sensor Wired to Relay Panel
Enable
More Aggressive
Less Aggressive
Oil