EWM1000plus EWM2000evo EWM3000new
2.4 AEG New Version with right selector and incorporated ON/OFF switch
2.4.1
Access to diagnostics system
2. Press buttons 1 and 2 simultaneously and then, holding them down, switch the appliance on
3. To exit the diagnostics system switch the appliance off, on and then off again.
2.4.2
Rapid reading of alarm codes
The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
Press buttons 1 and 2 simultaneously for at least 2 seconds: the LED switch off and then display the
sequence of flashes indicating the alarm.
The alarm sequence is displayed for the time in which the buttons are hold down
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps in memory the options previously chosen.
2.4.3
Cancelling the last alarm
It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-
occurs during the diagnostics control after the reparation of the appliance
1. Select diagnostics mode and turn the programme selector to the tenth position (reading of
alarm)
2. Press buttons 1 and 2 simultaneously.
3. Hold buttons 1 and 2 down (about 2 seconds).
QUICK GUIDE AND APPLIANCES LIST
1. Cancel the set programme and switch the appliance off.
by rotating the programme selector of one position clockwise.