Advanced Options - D-Link DVG-6004S User Manual

Voip gateway
Hide thumbs Also See for DVG-6004S:
Table of Contents

Advertisement

35

Advanced Options

There are two levels to enter Web. Administrator is able to change all settings. Web UI only
changes some settings.
NOTE: Enter new Login ID and password for two levels.
Web UI auto log out: When logging in a web page, if a user does not act within the effective
time range, the user will be disconnected from the web page to allow others to login.
Dial Wait Timeout: Use it to set the waiting time for the user's first key pressing when dialing
a number. The user will hear a busy tone if he/she does not press the first key within the set
time frame.
Inter Digits Timeout: Set the waiting time between each key pressing. The inputted
numbers will be dialed after the timeout.
Minimum DTMF ON Length (Dial on)/ Minimum DTMF OFF Length (Dial off - between
tones): Used to set dial tone when a call is being diverted to another extension.
DTMF Detection Sensitivity: Used to adjust the sensitivity of the telephone keys.
FXO Dial Type: Choose dialing type of FXO. There are DTMF and Pulse. ※
Pulse Dial Mark/Space Ratio: Duration and break of pulse dial ration. ※
FXO Impedance: Choose correct impedance in your country/area. ※