Ourdoor Unit Electronic Control P.c. Board - Mitsubishi Electric MXZ-18NV Service Manual

Inverter-controlled multi system split-type, heat pump air conditioners
Table of Contents

Advertisement

MXZ-18NV -
MXZ-18NV -
E1

Ourdoor unit electronic control P.C. board

12V DC
Power
supply
Electron
expansion
valve
12V DC pulse
shape
High-pressure
switch short
(Normal)
Evaporation
temperature
temperature
thermistor
thermistor
2.5~4V DC
Suction
temperature
temperature
thermistor
thermistor
Room A coil
Room A coil
thermistor
thermistor
2.5~4V DC
Room B coil
Room B coil
thermistor
thermistor
2.5~4V DC
Discharge
temperature
temperature
thermistor
thermistor
0.3~0.6V DC
Power
supply
5V DC
Discharge temperature thermistor
700
600
500
400
300
200
100
0
0
10
20
30
40
50
Temperature (;)
E2
2~3V DC
LED
220 / 240V Jumper wire
Short : 220V
Open : 240V
60
70
80
90
100 110 120
Room A serial
signal
Room B serial
0~24V DC
signal
0~24V DC
Fin temperature thermistor
200
180
160
140
120
100
80
60
40
20
0
0
10 20 30 40 50 60 70 80
Temperature (;)
2~3V DC
Power
supply
input
330V DC
Fuse 3A
Fin temperature
Fin temperature
thermistor
(RT 63)
Relay
(X64)
Outdoor
fan Hi
220-240V AC
Solenoid valve
220-240V AC
220-240V AC
Measure the
voltage under
the condition
of the connector
pluging.
Fuse 3.15A
Outdoor fan, solenoid valve
power supply input
220-240V AC
Gas pipe temperature thermistor
Evaporation temperature thermistor
Suction temperature thermistor
Defrost temperature thermistor
100
90
80
70
60
50
40
30
20
10
0
-20
-10
0
10
Temperature (;)
20
30
40
49