Mitsubishi Electric MXZ-18NV Service Manual page 14

Inverter-controlled multi system split-type, heat pump air conditioners
Table of Contents

Advertisement

REDR
X64
GRN/YLW
POWER SUPPLY
~/N 220-240V 50Hz
TB2
L
BLK
N
BLU
CIRCUIT BRAKER
TB3
INDOOR
N
BLU
(A) 12VDC
RED
UNIT
3
INDOOR
N
BLU
(B) 12VDC
ORN
UNIT
3
INDOOR
N
BLU
(C) 12VDC
YLW
UNIT
3
INDOOR
N
BLU
(D) 12VDC
BEN
UNIT
3
SYMBOL
C61
POWER FACTOR CAPACITOR
C62,63
SMOOTHING CAPACITOR
C65
OUTDOOR FAN CAPACITOR
CH
CRANKCASE HEATER
CT61,62
CURRENT TRANSFORMER
DS61
DIODE MODULE
DS62
DIODE STACK
F801
FUSE (1A)
F911
FUSE (1A)
L
REACTOR
L61
COMMON MODE CHOKE COIL
LEV A~D
EXPANSION VALVE
R
RESISTOR
RT61
DISCHARGE TEMPERATURE THERMISTOR
RT62
DEFROST TEMPERATURE THERMISTOR
RT63
FIN TEMPERATURE THERMISTOR
RT64
EVAPORATION TEMPERATURE THERMISTOR
NOTE:1. "- - - - " denotes the wiring at the site.
2 " "show the terminals with a lock mechanism, so they cannot be removed
when you pull the lead wire.
Be sure to pull the wire by pushing the locking lever(projected part) of the
terminal with a finger.
14
MODELS MXZ-32NV-
DS61
C61
RED
ORN
+
+
WHT
BLK
-
-
YLW
BLK
TB4
CT
61
4
6
BLK
X64
0
1
L61
LD62
LD61
F911
LDE
1 2
CN913
CN720
CN901
CN902
1 2
GRN/YLW
6
4
21S4
CN851
CN852
ELECTRONIC CONTROL P.C. BOARD
CN791
CN792
CN793
CN794
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
LEV A
LEV B
LEV C
LEV D
NAME
INDOOR AND OUTDOOR ELECTRICAL WIRING CONNECTION FIGURE
OUTDOOR UNIT
Indoor/outdoor connecting wire
3
D UNIT
N
3
C UNIT
N
3
B UNIT
N
3
A UNIT
N
N
L
MXZ-32NV-
E1
DS62
C63
C62
L
A
RED
+
+
ORN
K
-
WHT
YLW
NOISE FILTER
P.C.BOARD
2
C65
CN912
3 4
1 2
1 2 3 4 5 6
21S2
MF61
CH
CN722
CN663
CN662
1 2
3 4
1 2
1 2 3 4 5 6 7 8
63H1
63L
RT63
RT66
RT68
RT62
RT67
RT69
SYMBOL
RT65
SUCTION TEMPERATURE THERMISTOR
RT66,67
GUS PIPE TEMPERATURE THERMISTOR
RT68,69
GUS PIPE TEMPERATURE THERMISTOR
MC
COMPRESSOR
MF61
OUTDOOR FAN MOTOR (INNER FUSE)
SSR61,62
SOLENOID COIL RELAY
SSR63
CRANKCASE HEATER RELAY
T801
TRANSFORMER
TB2,3,4
TERMINAL BLOCK
X61,62,63
FAN MOTOR RELAY
X64,65
RELAY
X66,67
RELAY
21S2
SOLENOID COIL
21S4
R.V. COIL
63H1
HIGH PRESSURE SWITCH
63H2
HIGH PRESSURE SWITCH
63L
LOW PRESSURE SWITCH
INDOOR UNIT
D UNIT
Make all connections
C UNIT
as shown below.
B UNIT
Terminal block
3
2
GROUND
N
L
POWER SUPPLY
~/N 220-240V 50Hz
Power supply cord
A UNIT
E2
RED
YLW
-
V
MC
U
W
T801
TAB64
TAB65
CT62
TAB66
I.P.M P.C. BOARD
YLW
CN661
YLW
1 2 3 4 5 6 7 8
RT64
RT61
RT65
NAME
BRN
GRY
BLK
BLK
63H2
ORN
ORN
RELAY
P.C. BOARD
1.Slide the sleeve.
2.Pull the wire while
pushing the locking
lever.