Important Note - Potterton Mersey Super Installation And Service Instructions Manual

Gas fired water heater
Hide thumbs Also See for Mersey Super:
Table of Contents

Advertisement

FAULT FINDING - Page 21
SYMPTOM
SMELL OF COMBUSTION
PRODUCTS
SYMPTOM
UNEXPLAINED SHUT-DOWN OF THE APPLIANCE
This appliance contains an Energy Cut-Off Device which reacts when the water in the heat exchanger exceeds the
anticipated temperature limit. Although it is intended to guard against failure of the automatic gas valve, it may be
triggered inadvertently by other causes, especially during the summer months when the inlet water temperature is
unusually high.
However, if the energy cut-oft device reacts to a slowly closing automatic gas valve, the shut down of the appliance may
be accompanied by noises from the heat exchanger and pipework. The pressure relief valve located on top of the water
governor may also have vented water into the case. In this situation it is possible that STEAM will come out of the hot
water tap when turned on.
POSSIBLE CAUSE
Excessive resistance of push rod.
To ensure continued safe operation, we recommend that if the pressure relief valve has operated, it should be
replaced immediately
POSSIBLE CAUSE
1.
Faulty case or terminal seal.
2.
Failure to follow Instructions with
regards to openable windows and
doors.
SOLUTION
Exchange push rod and seals. Lubricate with Dow Corning
lll silicone grease and ensure free movement.

IMPORTANT NOTE

SOLUTION
1.
Check that the outer case seal -
Part No 10/17501 and terminal
seal - Part No 31/12299 are in
good condition, replace if
necessary. Ensure the outer
case is correctly positioned.
2.
Re-site the appliance.