Introduction - Potterton Suprima 30 HE Installation & Service Instructions Manual

Condensing central heating boiler
Table of Contents

Advertisement

1. Introduction

Important Installation Notes
The boiler is suitable for use with fully pumped
open vented and sealed systems with an indirect
coil type high efficiency cylinder.
The gas type, supply size and pressure must be
checked for suitability before connection.
Failure to install the condensate discharge
pipework correctly could affect the reliable
operation of the boiler.
For the boiler to operate correctly all air must be
vented from the system prior to commissioning
and the system itself must be suitably vented.
The system must be designed to always provide
a route for water to circulate between the boiler
flow and return.
For
optimum
boiler
performance must meet the requirements shown
on Page 15.
Failure to flush and add inhibitor to the system
may invalidate the boiler warranty.
Failure to commission the boiler correctly may
result in the installer being charged for any visits
made by Baxi Potterton.
© Baxi Heating UK Limited 2005 All rights reserved. No part of this publication
may be reproduced or transmitted in any form or by any means, or stored in any
retrieval system of any nature (including in any database), in each case whether
electronic, mechanical, recording or otherwise, without the prior written
permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner's permission to reproduce or make other
use of any part of this publication should be made, giving details of the proposed
use, to the following address:
The Company Secretary, Baxi Heating UK Limited, Pentagon House,
Sir Frank Whittle Road, Derby, DE21 4XA.
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a
copyright work may be liable to criminal prosecution and civil claims for damages.
4
intelligently applied technology
performance,
pump
Potterton Suprima HE
Suprima 30 HE G.C. No. 41 075 35
Suprima 40 HE G.C. No. 41 075 36
Suprima 50 HE G.C. No. 41 075 37
Suprima 60 HE G.C. No. 41 075 38
Suprima 70 HE G.C. No. 41 075 39
Suprima 80 HE G.C. No. 41 075 40
Suprima HE boilers are fully automatically controlled,
wall mounted, fan powered, balanced flue condensing
boilers using a cast iron primary heat exchanger.
Suprima HE boilers meet the requirements of Statutory
Instrument "The Boiler (Efficiency) Regulations 1993
No 3083" and deemed to meet the requirements of
Directive 92/42/EEC on the energy efficiency
requirements for new hot water boilers fired with liquid
or gaseous fuels:-
Type test for purpose of Regulation 5 certified by:
Notified Body 0087.
Product/Production certified by:
Notified Body 0086.
For use with Natural Gas (G20) only at 20mbar and for
use in GB/IE only.
CORGI
All CORGI registered installers carry a CORGI
identification card and have a registration number. You
can check your installer is registered by:-
• Telephoning 0870 401 2300
• Writing to 1 Elmwood, Chineham Business Park,
Crockford Lane, Basingstoke, RG24 8WG.
• Check online at www.corgi-gas-safety.com
Identification
To gain access to the identification labels, pull the door
down.
The data label is on a swing out plate located just
above the operating lights and temperature control
knob.
A seven digit version of the serial number is located on
the operating label attached to the rear of the door.
© Baxi Heating UK Limited 2005