Sweep Subsystem
HP 8360
User's Handbook
l
Queries the Data Questionable Event Register. This is a destructive
read.
STATus:QUEStionable:NTRansition <num>
l
l
Sets and queries the Negative TRansition Filter for the Data
Questionable Status Register. The STAT
STATus:QUEStionable:PTRansition <num>
l
STATus:QUEStionable:PTRansition?
l
Sets and queries the Positive TRansition Filter for the Data
Questionable Status Register. After STAT
set to 1s.
Interactions between dwell, sweep time, points, step size, and
frequency span are as follows:
SWEep:TIME = (5 ms + SWEep:DWELl) x (SWEep:POINts - 1)
FREQ:SPAN = SWEep:STEP x (SWEep:POINts - 1)
SWEep:xx:AUTO switches
TIME
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SWEep:CONTrol:STATe ONlOFFlllO
l
SWEep:CONTrol:STATe?
l
Sets and queries the state of the sweep control.
Normal source mode.
OFF
Use master slave source mode.
ON
*RST value is OFF.
SWEep:CONTrol:TYPE MASTerlSLAVe
l
SWEep:CONTrol:TYPE?
l
Sets and queries the synthesizer, whether it is in master or slave
mode. This applies in a dual source mode. *RST value is MASTer.
: PRESet value is 0.
US
: PRESet, all used bits are
US
Switch Action
No coupling between SWEep:DWELl,
SWEep:TIME and SWEep:POINts.
No coupling between SWEep:DWELl,
SWEep:TIME and SWEep:POINts.
When SWEEP:TIME or SWEEP:POINts
are changed, SWEep:DWELl =
(SWEep:TIME / (SWEep:POINts - 1)) - 5 mS.
SWEep:DWELl is limited to 100 ps, minimum.
= 100 ps (MINimum).
SWEep:TIME = 5.1 ms
x
Operating and Programming Reference S-49
(SWEep:POINts - 1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

83620a83622a83624a83623a83630a83640a ... Show all