Quadra-Fire QV36DC-A Owner's Manual page 17

Quadra-fire
Table of Contents

Advertisement

VENTING WITH ONE (1) 90° ELBOW
V
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
V+H=40' MAX. (12.4m)
NOTE: On vertical venting configurations
where the vertical component is over 10 feet
install the vertical baffl e included in the manual
bag assembly to improve fl ame appearance.
Figure 11. Venting with One 90° Elbow
VENTING WITH ONE (1) 90° ELBOW
V (FT.)
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
20' MAX. (6.2m)
V+H= 40' MAX. (12.4MM) H = 20' MAX. (6.2m)
o
NOTE: If a 90
elbow is
fi rst attached to the unit,
the maximum horizontal
run is 3-feet (914mm).
Figure 12. Venting with One 90° Elbow
H
2' MAX. (610mm)
4' MAX. (1.22m)
6' MAX. (1.86m)
8' MAX. (2.4m)
H = 8' MAX. (2.4m)
H (FT.)
5' MAX. (1.52m)
10' MAX. (3.1m)
15' MAX. (4.65m)
H
V
Quadra-Fire • QV36DC-A • 2161-900 Rev. B • 10/08
V
H
NOTE: For corner installations: A 6-inch (152mm)
section of straight pipe may need to be attached to
the fi replace before a 90
pipe to clear the top standoffs.
H
V
o
elbow, to allow the vent
17