Installation and Operation
Installation and Operation
WARNING: Shock Hazard
If the input plug is connected and utility power is present, the outlets will be
energized. The front panel ON/OFF button will not turn these outlets off.
Important:
PowerSource 1800 should be used or stored in a clean, temperature-
controlled, indoor area away from direct sunlight, moisture or conductive contaminants.
Allow a minimum of 3 inches of space around the unit for optimal ventilation.
Important:
PowerSource 1800 must be charged immediately before storage or
use. This will protect the battery inside from damage and will ensure extended usage run
time. A complete charge may take up to 15 hours when recharged from a 120 VAC wall
outlet.
CAUTION: Equipment Damage
Do not plug surge-protected power bars into
Do not connect an AC power source to the 120 VAC outlets.
Do not connect the unit's AC power cord to its 120 VAC outlets.
Operation Guide
Condition
Normal operation: Utility power is available and unit is
turned on. The internal battery is fully charged.
Backup power: Utility power is not available. Unit supplies
power from its internal battery.
Low battery warning: During backup power operation, the
internal battery is close to being completely discharged.
Overload shutdown: During backup power operation an AC
outlet overload was detected.
Under-voltage shutdown: During backup power operation
the battery power has been completely exhausted. No power
is available at the AC outlets.
Over-temperature warning: During backup power
operation, the unit is close to shutting down to protect its
internal circuitry from high temperatures.
Over-temperature shutdown: Unit has shut down to protect
its internal circuitry from high temperatures.
Recharging internal battery: Unit is recharging its internal
battery after utility power has been restored. Internal fan is
running.
4
the unit
's 120 VAC outlets.
LED status
AC Power LED and Charged/Charging LED
are solid green. Screen shows "FUL."
Battery LED is flashing amber.
Battery LED is flashing amber. Screen
shows Error code E05.
Fault LED on. Screen shows Error code E03. One beep per second. Unit shuts down
Fault LED on. Screen shows error code E01. One beep per second. Unit shuts down
Fault LED on. Screen shows error code E06. Beeps once every 2 seconds.
Fault LED on. Screen shows error code E04. One beep per second.
AC Power LED is green. Charged/Charging
LED flashes amber. Screen shows "CHG"
alternating with battery capacity (%).
To install PowerSource 1800:
1.
Plug the power cord directly into a wall outlet (not into a surge protector or
power strip).
2.
Connect your electronic devices or small household appliances to the five
AC outlets of the PowerSource 1800.
3.
Turn on the unit by pressing the Power button for at least half a second. The
green AC Power LED confirms that the PowerSource 1800 is on and ready
to provide backup power.
When the battery needs recharging, the LED screen flashes "CHG" 10 times,
then the battery capacity (%) once. This pattern of flashing continues until
the battery capacity reaches 100% and "FUL" appears on the screen.
Backup Power Feature
The unit's five
outlets are permanently backed up by the internal battery
120 VAC
when utility power is not available. To activate the AC outlets for backup
operation, turn on the unit using the Power button. During a power outage or
other utility problem (such as brownouts and over-voltages), PowerSource 1800
will keep running the connected products for up to 10 hours, depending on the
power draw of your application (see "Run Time on Typical Products" and "Run
Time for Combinations of Products"). When utility power is restored, the unit
automatically recharges its internal battery.
Important:
When connected to utility power,
power from its internal battery when the utility voltage falls below 105 VAC.
Alarm status
None
One beep when the power outage
occurs.
Beeps once every 2 seconds.
after 10 seconds.
after 10 seconds.
No sound
the unit
automatically provides AC
Alarm stops sounding when...
Not applicable
Utility power becomes available; unit resumes
normal operation or when it is turned off.
Utility power becomes available; unit resumes
normal operation or when it is turned off.
Not applicable
Not applicable. Unit starts recharging the
internal battery when utility power is restored.
Turn on the unit to restore normal operation.
Better ventilation to the unit is provided, or the
unit enters over-temperature shutdown, or the
unit is turned off.
The unit is turned off or when the unit shuts
down.
Not applicable. Screen shows "FUL" when unit
is completely charged.
975-0345-01-01