Duracell PowerSource 1800 Owner's Manual

Duracell PowerSource 1800 Owner's Manual

Hide thumbs Also See for PowerSource 1800:

Advertisement

Notice of Copyright
©2010 Duracell. DURACELL® is a registered trademark of The Gillette Company,
used under license. All rights reserved. All logos and trademarks are used for
identification purposes only and may be trademarks or registered trademarks
of their respective holders.
Date and Revision
October 2010 Revision 20101027
Part Number
975-0345-01-01
Part Number
852-1807
Contact Information
Phone:
1 800 842 2127
Website:
www.DuracellPower.com
975-0345-01-01

IMPORTANT SAFETY INSTRUCTIONS

Operating the Duracell® PowerSource 1800 incorrectly or misusing it may
damage the equipment or create hazardous conditions for the user.
SAVE THESE INSTRUCTIONS
instructions for the PowerSource 1800. They need to be followed during
installation and operation of this product.
WARNING: Shock hazard.
Keep away from children. PowerSource 1800 generates the same potentially
lethal AC power as a normal household wall outlet.
Do not insert foreign objects into the AC Outlet or the ventilation holes.
Do not expose this product to water, rain, snow, or spray.
WARNING: Risk of injury or loss of life
Do not use PowerSource 1800 in connection with life support systems or other
medical equipment or devices.
WARNING: Explosion hazard
Do not use this product where there are flammable fumes or gases.
WARNING: Electric shock and energy hazard
Do not remove cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.
WARNING: Energy and burn hazard
A battery can present a risk of burn from high short-circuit current.
CAUTION: Risk of damage to the PowerSource 1800
The unit will not work when connected to any AC load that has its neutral
conductor connected to ground. Such loads include AC distribution wiring and
house wiring.
Owner's Guide
—This manual contains important
1

Advertisement

Table of Contents
loading

Summary of Contents for Duracell PowerSource 1800

  • Page 1: Important Safety Instructions

    • Do not expose this product to water, rain, snow, or spray. WARNING: Risk of injury or loss of life Do not use PowerSource 1800 in connection with life support systems or other medical equipment or devices. WARNING: Explosion hazard Do not use this product where there are flammable fumes or gases.
  • Page 2: Fcc Information To The User

    15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential When the PowerSource 1800 is supplying backup power from its batteries, its installation. This equipment generates, uses and can radiate radio frequency...
  • Page 3 Feature Description Fault LED illuminates red when PowerSource 1800 has an operation fault. Power button turns PowerSource 1800 on and off when utility power is not available. • Pressing and holding the Power button for at least half a second turns the unit on or off when utility power is not present.
  • Page 4 Turn on the unit by pressing the Power button for at least half a second. The energized. The front panel ON/OFF button will not turn these outlets off. green AC Power LED confirms that the PowerSource 1800 is on and ready to provide backup power.
  • Page 5: Battery Replacement

    1800 during backup power mode, press the Select button and view the Output Power (W) on the screen. During a power outage, maximizing PowerSource 1800 run time is essential to keep your home/small office running or to stay connected to the outside world To test the PowerSource 1800 backup power capabilities after installing the unit, through TV and radio news or cellphone/cordless phone.
  • Page 6 Recycling Recycling If it’s rechargeable, it’s recyclable! Battery-Biz is committed to environmental responsibility and has established a program for recycling Duracell rechargeable battery-related products. For instructions on how to recycle this product visit www.rbrc.org 975-0345-01-01...
  • Page 7: Understanding Error Codes

    Troubleshooting Understanding Error Codes If the products connected to PowerSource 1800 do not operate and the alarm is sounding, check PowerSource 1800 LED screen for an error code. Low voltage shutdown because battery is discharged. Recharge battery by plugging the AC power cord into a wall outlet.
  • Page 8: Electrical Specifications

    Peak AC output power 1800 W Surge capacity 2880 W If found to be defective, this Duracell® product will be replaced without charge when returned to Battery-Biz. This guarantee does not apply to damage from misuse or abuse Output voltage (nominal) 120 VAC beyond normal usage.
  • Page 9: Contacting Customer Support

    If you experience any problems or have any questions regarding your One Year Limited Warranty DURACELL® product, free technical support is available. Prior to calling, This product carries a limited warranty against defects in material and workman- please review the technical support tips below.