Operating Limits - Cobra CPI 2575 Operating Instructions Manual

2500 watt power inverter
Table of Contents

Advertisement

Main Icons
Operating Indicators
Operation
Intro
Operation
Customer
Assistance
High Temperature
Main Icons
Installation
Intro
Operation
Secondary Icons
Installation
Notice
Caution
Secondary Icons
Notice
18
Warranty
Over Temperature Protection –
If the internal inverter temperature
rises above the alarm threshold,
the meter will flash as shown, an
alarm will sound to indicate Over
Notes
Temperature Protect, and the unit
will continue to operate. If the
Customer
Warranty
Assistance
internal temperature rises to 40ºC
(104ºF), the inverter will shut down
to protect itself, the meter will
flash as shown and the alarm will
Notes
Warning
continue to sound.
NOTE Internal inverter temperature
can rise due to being operated in a
high heat environment or due to the
Caution
Warning
fan or vents being blocked during
operation (even in relatively cool
outside air).
To restore normal operation, turn
the unit Off and allow it to cool.
The inverter will automatically
return to normal operation after
it has cooled.
Main Icons

Operating Limits

Operation
Intro
Operation
Customer
Operating Limits
Assistance
Power Output
The inverter can deliver 2500 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
Installation
resume operation at 2500 watts. Note: The wattage
rating applies to resistive loads.
Secondary Icons
The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps,
and other motor-operated equipment require very high
surge currents to start. The inverter may not be able
Notice
Caution
to start some of these motors even though their rated
current draw is within the inverter's limits. The inverter
will normally start single phase induction motors rated
at one-half HP or less.
Input Voltage
The inverter will operate from input voltage ranging
from 10 volts to 15 volts. Optimum performance will
occur when the voltage is between 12 volts and 14 volts.
If the voltage drops below 10.5V+/- 0.3V, an audible low
battery warning will sound. The inverter will shut down if
the input voltage drops below 9.5V+/- 0.3V. This protects
the battery from being over-discharged. It will restart
when the input voltage exceeds 12V+/- 0.3V.
The inverter will also shut down if the input voltage
exceeds 15.5V +/- 0.5V. This protects the inverter
against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.
Warranty
Notes
Warning
Nothing Comes Close to a Cobra
19