QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions (H x W x D)
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per 3 power supplies non
redundant)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output (per
Power Supply Output
Power Supply Output
Power Supply Output
power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
DA - 13046
Worldwide — Version 4 — May 21, 2008
12.04 x 17.32 x 27.4 in (30.58 x 44 x 69.6cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, 2 power
supply, and 4 processor
modules installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls
Click on the system of interest. Example: DL785 G5
Follow the instructions of the next screens
Rated Steady-State Power
Maximum Peak Power
Non-operating
Operating
Non-operating
HP ProLiant DL785 Generation 5 (G5)
HP ProLiant DL785 Generation 5 (G5)
HP ProLiant DL785 Generation 5 (G5)
HP ProLiant DL785 Generation 5 (G5)
160lb (72 kg)
147 lb (67 kg)
90 - 132 VAC
180 - 264 VAC
24A @ 100 VAC
14A @ 200 VAC
47 to 63 Hz
2400W @ 100-120 VAC
2800W @ 200-240 VAC
8189 BTU/hr @ 100-120 VAC
9554 BTU/hr @ 200-240 VAC
800 W (at 100 VAC),
1200 W (at 200 VAC)
800 W (at 100 VAC),
1200 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 60° (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bult temperature, non-
condensing.
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non
condensing.